Error Code Description
450A 308A Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
450A 308B Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
450A 308C Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
450A 308D Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
450A 308E Memory subsystem and processor subsystem
tests detected fault in 4 GB outer memory book
450A 30BD Memory subsystem and processor subsystem
tests detected fault in 8 GB or 16 GB CUoD
inner memory book
450A 30C3 Memory subsystem and processor subsystem
tests detected fault in 32 GB or 64 GB CUoD
inner memory book
450A 30C6 Memory subsystem and processor subsystem
tests detected fault in 8 GB or 16 GB CUoD
outer memory book
450A 30CC Memory subsystem and processor subsystem
tests detected fault in 32 GB or 64 GB CUoD
outer memory book
450B 248B Memory subsystem and wire tests detected
fault in operator panel
450B 25C0 Memory subsystem and wire tests detected
fault in system backplane
450B 25C1 Memory subsystem and wire tests detected
fault in 1.0 GHz clock card
450B 25D9 Memory subsystem and wire tests detected
fault in L3 VPD card used with 1.1 GHz MCM
and 1.3 GHz MCM
450B 25E7 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
450B 25E8 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
450B 25F1 Memory subsystem and wire tests detected
fault in L3 VPD card used with 1.3 GHz MCM
450B 25F9 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
450B 269A Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
450B 28B0 Memory subsystem and wire tests detected
fault in I/O subsystem PCI backplane
450B 28B1 Memory subsystem and wire tests detected
fault in I/O subsystem DASD backplane
450B 302A Memory subsystem and wire tests detected
fault in 8 GB memory book (inner)
Action/
Possible Failing FRU
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 327.
Go to "MAP 1544: Inner L3 Module Problem
Isolation" on page 327.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329.
Go to "MAP 1545: Outer L3 Module Problem
Isolation" on page 329.
Operator panel
Location: U1.17-L1
System backplane
Location: U1.18-P1
Clock card
Location: U1.18-P1-X5
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
Go to "MAP 1548: Memory and Processor
Problem Isolation" on page 335.
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Chapter 5. Error Code to FRU Index