IBM pSeries 690 Service Manual page 796

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Please wait....
Fru type
= 00f6 BPC-RH
Cage id
= ff BPA
Port
= A
Fru id
= 80 BPC
Location Code = U1.35-P1-X4
Code level
= 0000255e
Status
= 01 Successfully collected
Fru type
= 0048 DCA-RHP
Cage id
= 00 CEC Cage
Fru id
= 90 DCA 1
Location Code = U1.18-P1-V1
Code level
= 00000027
Status
= 01 Successfully collected
Fru type
= 0050 MDA-X
Cage id
= 00 CEC Cage
Fru id
= 98 MDA 1
Location Code = U1.18-X1
Code level
= 00000007
Status
= 01 Successfully collected
Fru type
= 0047 DCA-BC
Cage id
= 01 I/O Drawer 1
Fru id
= 90 DCA 1
Location Code = U1.9-V1
Code level
= 0000fb23
Status
= 01 Successfully collected
Fru type
= 0054 MDA-BC
Cage id
= 01 I/O Drawer 1
Fru id
= 98 MDA 1
Location Code = U1.9-V1
Code level
= 00000005
Status
= 01 Successfully collected
v LED Control Menu
This menu displays the state of the processor subsystem disturbance or system attention LED and the
fault/identify LED on the I/O subsystem(s). Use this menu to toggle the attention/fault LEDs between
identify (blinking) and off. Option 1 is available only when the system is in the error state (the CEC is
powered on and the service processor menus are available). Option 1 is not available when the system
is in standby.
An example of this menu follows:
LED Control Menu
1. Set/Reset Identify LED state
2. Clear System Attention Indicator
98. Return to Previous Menu
Enter LED index
0 >
The processor subsystem disturbance or system attention LED is located on the operator panel in the
media drawer. The I/O drawer fault/identify LED is located on the front of each I/O subsystem.
If option 1 is selected, a list of location codes of the I/O subsystems and the CEC drawer displays. The
screen will be similar to the following:
776
Eserver pSeries 690 Service Guide

Advertisement

Table of Contents
loading

Table of Contents