Error Code Description
1011 3114 PCI Backplane
1011 3115 Operator Panel
1011 3118 SPCN
1011 34A2 SPCN
1011 8400 VPD Configuration
1011 8401 VPD access problem
1011 8402 VPD access problem
1011 8403 VPD level mismatch
1011 8404 MCM 2 VPD mismatch
1011 8405 MCM 1 VPD mismatch
1011 8406 MCM 3 VPD mismatch
Action/
Possible Failing FRU
Was the primary I/O book at location
U1.18-P1-H2 changed prior to the most recent
reboot of the system?
YES
This error code may be due to
down-level system power control
network firmware on the new primary
I/O book. The system will automatically
update the system power control
network firmware to the correct level.
This error code should be cleared after
the next reboot.
NO
Replace the primary I/O book,
Location: U1.18-P1-H2
1. Operator panel,
location: U1.17-L1
2. Primary I/O book,
Location: U1.18-P1-H2
Primary I/O book
Location: U1.18-P1-H2
Primary I/O book
Location: U1.18-P1-H2
Primary I/O book
Location: U1.18-P1-H2
1. System VPD module
Location: U1.17-L1-N1
2. Primary I/O book
Location: U1.18-P1-H2
Primary I/O book
Location: U1.18-P1-H2
1. System VPD module
Location: U1.17-L1-N1
2. Primary I/O book
Location: U1.18-P1-H2
1. MCM 2 and VPD card,
Locations: U1.18-P1-C4 and U1.18-P1-H2.4
2. Primary I/O book
Location: U1.18-P1-H2
1. MCM 1 and VPD card,
Locations: U1.18-P1-C3 and U1.18-P1-H2.5
2. Primary I/O book
Location: U1.18-P1-H2
1. MCM 3 and VPD card,
Locations: U1.18-P1-C2 and U1.18-P1-H2.6
2. Primary I/O book
Location: U1.18-P1-H2
Chapter 5. Error Code to FRU Index