Module Rear
Ports
Description
ANALOG
RJ45 socket. Used for connection to analog trunks. Ports can be configured as either loop-start or
390
ground-start trunks through the IP Office configuration.
In the event of power failure, Analog ports 1 and 2 are directly connected to analog extension ports
PF1 and PF2 respectively. If used the connected phones must be clearly labeled as power failure
devices. This is only supported for loop-start analog trunks.
DC I/P
DC power input port. Used for connection of the power lead from an Avaya 40W external power supply
393
unit supplied with the expansion module. A locale specific
external PSU is required but is not supplied with the module.
DTE
25-Way D-Type socket. For Avaya use only.
EXPANSION
RJ45 Socket. Used for direct connection to an Expansion port on an IP Office control unit using the
395
Expansion Interconnect cable supplied with the module.
PF
RJ45 socket. Power failure analog extension ports. See Analog section above.
397
Ground point. Used for connection of a
screw is not present, the top-center cover screw should be used instead.
· IMPORTANT
In all IP Office installations, any module being used for analog trunk connections must be connected
to a
·
Within the Republic of South Africa and in areas of high lightning risk, any module using analog
trunk connections must be connected to a
45
Part Codes and Related Equipment
All expansion modules are supplied with a base software level and should be upgraded to match the core software of the
control unit in the IP Office system. Expansion modules include an external power supply unit (PSU) and an appropriate
interconnect cable. They do not include a locale specific power cord for the external PSU or any phone extension cables.
Item
IP400 Analog Trunk 16
IEC60320 C7 Power Cord
IP400 Rack Mounting Kit
Installing IP500/IP500 V2
IP Office 9.0
functional earth
.
44
WARNING
.
Variant
America
Europe
New Zealand
CEE7/16
BS1363
NEMA1-15
Korea
System Components: IP400 Expansion Modules
IEC60320 C7 power cord
functional earth
if required. On older modules where this
44
protective ground
44
Country
America
Europe
New Zealand
Europe
United Kingdom
America
Korea
All
for the
39
and to
surge protection equipment
SAP Code
700211360
700241680
700241698
700213382
700213374
700213390
700254519
700210800
15-601042 Issue 28c (19 August 2013)
Page 267

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip500

Table of Contents