8.5.3 Defaulting Security using the RS232 Port

Read and note the warnings regarding
WARNING
·
Use of the RS232 port should only be performed if absolutely necessary and only if the actions cannot be completed
using IP Office Manager or IP Office Web Manager. In all cases, you must make every effort to ensure that you
have a backup copy of the system configuration.
To default a system' security settings via DTE
This process defaults the IP Office's security settings but does not alter its configuration settings.
1. Attach the serial cable between the PC and the DTE port on the IP Office control unit.
2. Start the terminal program on your PC. Ensure that it has been setup as listed in DTE Port Settings. Within a
HyperTerminal session, the current settings are summarized across the base of the screen.
3. Enter AT (note upper case). The control unit should respond OK.
4. Enter AT-SECURITYRESETALL.
5. You will be prompted to confirm the control unit's MAC address before continuing. Enter the address.
6. The control unit will respond OK when the action has been completed.
7. Close the terminal program session.
8. IP Office Manager can now be used to receive and edit the control unit's now defaulted security settings.