8.16.2 Erasing Core Software Using Debug

Read the note and the warnings regarding
WARNING
·
Use of the RS232 port should only be performed if absolutely necessary and only if the actions cannot be completed
using IP Office Manager or IP Office Web Manager. In all cases, you must make every effort to ensure that you
have a backup copy of the system configuration.
To erase the core software using Debug
1. Run IP Office Manager.
· In the BOOTP entries, check that there is an entry that matches the MAC Address, IP Address and .bin file
used by the system. An entry is normally automatically created when a configuration has been loaded from
that IP Office. .
· If an entry is not present, create a new entry manually. The first two details can be found in the Control
Unit settings in the configuration file. Then close and restart IP Office Manager.
· Under File | Preferences ensure that IP Office Manager is set to 255.255.255.255. Also check that Enable
BootP Server is checked.
· Select View | TFTPLog.
· Check that the required .bin file is present in Manager's working directory.
2. Attach the serial cable between the PC and the RS232 DTE port on the IP Office control unit.
a. Start the terminal program on your PC. Ensure that it has been setup as listed in RS232 DTE Port Settings.
Within a HyperTerminal session, the current settings are summarized across the base of the screen.
b. Enter AT (note upper case). The control unit should respond OK.
c. Enter AT-DEBUG. The control unit should response with the time and date and then Hello> to show it is ready
to accept commands.
3. To erase the current configuration in RAM memory enter upgrade.
4. The IP Office will erase its current software and then send out a BootP request on the network for new software. IP
Office Manager will respond and start transferring the software using TFTP.
Installing IP500/IP500 V2
IP Office 9.0
erasing the core software
before using this process.
183
15-601042 Issue 28c (19 August 2013)