Reset Button; Aux Button - Avaya IP500 V2 Installation Manual

Hide thumbs Also See for IP500 V2:
Table of Contents

Advertisement

8.13 Reset Button

The IP500 and IP500 V2 control units have a Reset button. Pressing the button while the control unit is starting up will
pause the start up until the button is released. The effect of pressing the button during normal operation will depend on
how long the button is pressed and is indicated by the CPU LED.
Press Duration
CPU LED
(seconds)
0 to 5.
Off
5 to 10.
Orange
10 to 30.
Flashing orange Erase Configuration
30 to 40.
Red
Over 40.
Flashing green

8.14 AUX Button

IP500 V2 control units have an AUX button. This button can be used as follows.
· If pressed during a restart of the control unit, the control unit
System SD card.
· If pressed for more than 5 seconds when a system is running, the control unit shuts down for 10 minutes.
Installing IP500/IP500 V2
IP Office 9.0
Action
None
Reboot When Free
Erase All.
None
Summary
None.
Reboot when free with new incoming/outgoing call
barring. A reboot using the reset button is recorded in
the Audit Trail.
Erase the configuration, alarm log and audit trail.
Immediate reboot without waiting for active calls to end.
See
Erasing the configuration
Erase configuration, alarm log and core software. See
Erasing the Operational Software
None.
skips booting
from the /primary folder on the
124
15-601042 Issue 28c (19 August 2013)
Additional Processes: SNMP
for full details.
152
for full details.
183