Boot Alarms
The following apply if the IP500 V2 boots using software other than that in its System SD /primary folder:
· An alarm will be shown in the System Status Application. It will also generate an alarm if the card in any slot is not
compatible. These alarms are also output as SNMP, Syslog or email alarms.
· The IP Office Manager Select IP Office menu will display an
using software other than from the System SD card's primary folder.
· The configuration can be read but will be read only. Attempting to send a configuration to the system will cause the
error message Failed to save configuration data. (Internal error).
Bypassing the System SD Card Primary Folder
The control unit can be forced to bypass the System SD card's /primary folder and non-volatile memory when starting.
This is done by pressing the Aux button while applying power to the control unit.
This action may be necessary if, following an upgrade of the IP Office system, it is determined that a roll back to the
previously backed up firmware and configuration is required. Using the Aux button should restore system operation using
the /backup folder files while the installer then restores the contents of the /primary folder to a previous release.
Installing IP500/IP500 V2
IP Office 9.0
SD Card Management: Booting from the SD Cards
icon indicating that the IP Office system is running