4.5.3 Inserting IP500 Base Cards

Having prepared each IP500 base card by adding any
be inserted into the control unit.
Warnings
·
· Correct anti-static protection steps should be taken while handling circuit boards.
· Cards must never be added or removed from the control unit while it has power connected.
· Tools Required
· o 5mm Flat-blade screwdriver.
· o Anti-static wrist strap and ground point.
Installing an IP500 Card
1. Check that there is no power to the control unit.
2. Using a flat-bladed screwdriver, remove the cover from the slot on the front of the control unit that will be used for
each card being installed. This cover is no longer required but should be retained until installation has been
completed.
3. Allowing the card to rest against the bottom of the slot, begin sliding it into the control unit. When half inserted,
check that the card rails have engaged with the slot edges by trying to gently rotate it. If the card rotates remove it
and begin inserting it again.
4. The card should slide in freely until almost fully inserted. At this point apply pressure at the base of the front of the
card to complete insertion.
5. Using a flat-bladed screwdriver secure the card.
Installing IP500/IP500 V2
IP Office 9.0
trunk daughter card
or
83
IP400 legacy card
, the base card can
85
15-601042 Issue 28c (19 August 2013)
Page 86