Lamp / Inverter PCB

1. Remove the PANEL COVER. (See page 5-8.)
2. Remove the REAR COVER and SHIELD PLATE. (See page 5-7.)
3. Remove the Rx exit cover. (See page 5-10.)
4. Remove the two Inner cover A mounting screws, then remove the INNER COVER A.
5. Disconnect the all harnesses from the Main control PCB.
6. Remove the four ADF unit mounting screws, then remove the ADF unit.
7. Put the ADF unit upside-down.
8. Peel the scanner cover (black film) from the scanner unit.
9. Remove three Scanner frame mounting screws and disconnect one connector. Then remove the
SCANNER FRAME.
Scanner cover (Black film)
Scanner frame
5-31