Muratec F-360 Field Engineering Manual page 60

Facsimile system
Hide thumbs Also See for F-360:
Table of Contents

Advertisement

Memory Switch 20 - Reception
Initial
Switch
Setting
Data error rate
7
0
0: 10%
1: 20%
Pause one second after
sending CED
6
0
0: No (75 ms)
1: Yes (1 sec)
5
0
Not used
4
0
Not used
Receive speed (kbps)
3
1
Maximum receive speed may be slowed to compensate for poor phone lines.
2
1
2.4 4.8 7.2 9.6 12 14.4 16.8 19.2 21.6 24 26.4 28.8 31.2 33.6
0
1
0
0
0
0
1
0
Memory Switch 21 - Reception
Initial
Switch
Setting
7
0
Not used
6
0
Factory use only
5
0
Factory use only
T1 timer
0: 35 sec
4
0
1: 20 sec
Print image data when post
message is not received after
3
1
receiving RTC signal
0: No
1: Yes
Disable ITU-T superfine
reception
2
0
0: Yes
1: No
G3 echo receive.
Adjusts the delay between detection of training/TCF and sending of CFR.
1
0
Switch 1
0
1
Switch 0
Adjust
0
0
0
0
0
0
0
0
0
1
1
1
0
1
1
0
0
1
1
0
1
0
1
0
Adjust
100 ms 500 ms 800 ms 1200 ms
0
0
0
1
Usage/Comments
Determines the allowable number of erred lines out
of total lines received in a document.
A 2100 Hz CED signal disables echo suppression in
some telephone equipment. When set to "1", the
unit pauses one second after sending CED, which
allows echo suppression to restart. This may help
with problematic overseas reception.
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
Usage/Comments
Adjusts the T1 time-out. After the machine dials the
remote machine's phone number, it begins sending
CNG and waits this amount of time before
disconnecting the line.
If the received document includes the RTC, the unit
prints the data even though the following protocol is
not successful.
Set to "1" if a compatibility error occurs because the
transmitting machine does not understand the
extended frame for ITU-T superfine resolution.
(Note: Setting this switch to "1" will disable superfine
mode.)
1
1
0
1
3-35
1
1
1
0
1
1
1
0
0
1
0
1

Advertisement

Table of Contents
loading

Table of Contents