Unique Switch 30 - Modem
Initial
Switch
Setting
Factory use only
7
0
Factory use only
6
0
3429 baud symbol rate when
communicating at V.34
5
1
0: No
1: Yes
3200 baud symbol rate when
communicating at V.34
4
1
0: No
1: Yes
3000 baud symbol rate when
communicating at V.34
3
1
0: No
1: Yes
2800 baud symbol rate when
communicating at V.34
2
1
0: No
1: Yes
Factory use only
1
0
2400 baud symbol rate when
communicating at V.34
0
1
0: No
1: Yes
Unique Switch 31 - Modem
Initial
Switch
Setting
7
0
Forced 2400 symbol rate
when probing SNR is
6
0
adverse
5
0
4
1
3
0
2
1
1
0
0
0
Adjust
If the error frame occurs because of the symbol
rate is too high, setting this switch to "1" masks that
symbol rate and decreases the occurrence of error
frame.
See above (switch 5 to 2 of Memory switch 30).
Adjust
SNR means that Signal Noise Ratio.
If the SNR is less than the threshold you set, the
modem overrides the bandwidth evaluation
algorithm and forces the symbol rate to2400 baud.