Muratec F-360 Field Engineering Manual page 45

Facsimile system
Hide thumbs Also See for F-360:
Table of Contents

Advertisement

Machine Parameter 72
Initial
Switch
Setting
Scanning slice level
7
0
adjustment in Super-Fine
resolution for transmission
Note: This slice level setting
6
0
is only effect for the super-
fine resolution. If you want to
adjust slice level for all
5
0
resolution modes, adjust the
Machine parameter 80.
4
0
3
0
2
0
1
0
0
0
Machine Parameter 73
Initial
Switch
Setting
Scanning slice level
7
0
adjustment for copying in the
mode without Grayscale
6
0
Note: This slice level setting
is only effect for the copying
resolution. If you want to
adjust slice level for all
5
0
resolution modes, adjust the
Machine parameter 80.
4
0
3
0
2
0
1
0
0
0
Adjust
Switch 76543210
Adjust
Switch 76543210
3-20
Usage/Comments
00111111
Darkest setting
|
|
00000010
00000001
00000000
Initial setting
11111111
11111110
|
|
11000000
Lightest setting
Usage/Comments
00111111
Darkest setting
|
|
00000010
00000001
00000000
Initial setting
11111111
11111110
|
|
11000000
Lightest setting