Muratec F-360 Field Engineering Manual page 40

Facsimile system
Hide thumbs Also See for F-360:
Table of Contents

Advertisement

Machine Parameter 50
Initial
Switch
Setting
Adjustment for the scanning
7
0
stretching and squeezing
from ADF and FBS.
(Horizontal)
6
0
The plus setting stretches the
image data and the minus
setting squeezes it.
5
0
Each setting changes by
0.1%
4
0
3
0
2
0
1
0
0
0
Machine Parameter 51
Initial
Switch
Setting
Adjustment of the scanning
7
0
stretching and squeezing for
ADF. (Vertical)
The plus setting stretches the
6
0
image data and the minus
setting squeezes it.
Each setting changes by
5
0
0.1%
4
0
3
0
2
1
1
1
0
0
Adjust
Switch 76543210
Adjust
Switch 76543210
3-15
Usage/Comments
Settings
01111111
12.7 % Maximum
:
00100000
3.2 %
:
00011000
2.4 %
:
00010000
1.6 %
:
00001000
0.8 %
:
0.0 % ← Initial setting
00000000
:
10001000
-0.8 %
:
10010000
-1.6 %
:
10011000
-2.4 %
:
10100000
-3.2 %
:
10111000
-12.7 %
Usage/Comments
Settings
01111111
12.7 % Maximum
:
00011000
2.4 %
:
00010000
1.6 %
:
00001000
0.8 %
:
0.5 % ← Initial setting
00000110
:
00000000
0.0 %
:
10001000
-0.8 %
:
10010000
-1.6 %
:
10011000
-2.4 %
:
10111000
-12.7 %
Minimum
Minimum

Advertisement

Table of Contents
loading

Table of Contents