Unique Switch 15 - Transmission
Initial
Switch
Setting
Not used
7
0
Not used
6
0
Factory use only
5
0
Factory use only
4
0
Not used
3
0
Not used
2
0
Not used
1
0
Factory use only
0
0
Unique Switch 16 - Transmission
Initial
Switch
Setting
Available *, # and space
upon F-code SUB/SEP
7
1
registration
0: No
1: Yes
Available *, # and space
upon F-code communicating
6
1
0: No
1: Yes
Available space in F-code ID
5
0
0: No
1: Yes
F-code sub-frame off
4
1
0: Send
1: Not send
Send F-code box's TTI
3
0
0: No
1: Yes
2
0
Not used
Retrieve document
1
0
0: No
1: Yes
Ignore F-code bit
0
1
0: No
1: Yes
Note: The "F-code communication" is possible the SecureMail and Polling operation using the F-code
(SUB/SEP/PWD/SID). However, it is not based on T.33 recommendation.
Adjust
Adjust
Determines if the unit checks the * (asterisk), #
(sharp) and space upon F-code SUB (sub-
addressing) /SEP (password) registration.
Determines if the unit checks the * (asterisk), #
(sharp) and space upon F-code communicating.
Determines if the space is checked in F-code ID.
Do not send the sub-address and password of F-
code box at the point of sending DCS signal after
EOM signal.
Transmit the sub-address and box name of F-code
box with F-code polling document.
Retrieve the document received in F-code
SecureMail box by polling transmission.
Neglect SEP bit of DTC signal or SUB bit of DCS
signal at F-code polled transmission.