Machine Parameter 12
Initial
Switch
Setting
ADF scanner registration
7
0
adjustment (Horizontal)
Adjusts the start point to
scan the document.
6
0
The plus setting increases
the left margin and the minus
setting decreases it.
5
0
Each setting changes by
0.5 mm.
4
0
3
0
2
0
1
0
0
0
Machine Parameter 14 <- F-320 Only)
Initial
Switch
Setting
7
0
Adjustment of the scanning
width (ADF)
6
0
5
0
Adjust the scanning width
4
0
with this switch.
3
0
2
0
Adding the plus setting
1
0
widens the scanning width
0
0
and the minus setting
narrows scanning width.
Each setting changes by
0.085 mm.
Adjust
Switch 76543210
Adjust
Switch 76543210
3
Usage/Comments
Settings
00000111
3.5 mm
00000110
3.0 mm
00000101
2.5 mm
00000100
2.0 mm
00000011
1.5 mm
00000010
1.0 mm
00000001
0.5 mm
00000000 Standard
10000001
-0.5 mm
10000010
-1.0 mm
10000011
-1.5 mm
10000100
-2.0 mm
10000101
-2.5 mm
10000110
-3.0 mm
10000111
-3.5 mm
Usage/Comments
Settings
00111111
+ 5.355 mm
00111110
+ 5.270 mm
00111101
+ 5.185 mm
00000010
+ 0.170 mm
00000001
+ 0.085 mm
standard ← Initial setting
00000000
− 0.085 mm
10000001
− 0.170 mm
10000010
− 5.185 mm
10111101
− 5.270 mm
10111110
− 5.355 mm
10111111
Maximum
← Initial setting
Minimum
Maximum
Minimum

Advertisement