Muratec F-360 Field Engineering Manual page 55

Facsimile system
Hide thumbs Also See for F-360:
Table of Contents

Advertisement

Memory Switch 05 - Dialer
Initial
Switch
Setting
7
0
Factory use only
Ring signal detect time
6
1
5
1
4
0
Number of CI signal
detection in Fax/Tel Ready
mode
3
0
0: Detect 1 time
1: Detect 2 times
Dual ring detection
2
0
0: No
1: Yes
Long ring detection
1
0
0: No
1: Yes
Frequency of the CI signal
detection
0
1
0: No
1: Yes
Memory Switch 06 to 09 - Dialer
Initial
Switch
Setting
Not used
7
0
Not used
6
0
Not used
5
0
Not used
4
0
Not used
3
0
Not used
2
0
Not used
1
0
Not used
0
0
Adjust
Sets the time that an incoming ring will not be
detected after hanging up. (Fax/Tel Ready mode
only.)
Switch 6 5 4
Select the number of detection times of CI signal in
the Fax/Tel Ready mode or in the ringer silent
mode. Incoming calls are answered according to
this setting regardless of the number of rings
chosen in the User Settings.
When enabled, the unit is able to auto answer an
incoming ring with an off time of 120 - 60 ms.
Allows the unit to respond to an incoming ring if the
ring on-time is longer than 3.5 seconds.
When disabled, the unit will not check the frequency
of the incoming CI signal.
Adjust
3-30
Usage/Comments
0 0 0
100 ms
0 0 1
200 ms
0 1 0
300 ms
0 1 1
400 ms
1 0 0
500 ms
1 0 1
600 ms
1 1 0
700 ms
1 1 1
800 ms
Usage/Comments