Unique Switch 93 - Miscellaneous
Initial
Switch
Setting
Not used
7
0
Not used
6
0
Not used
5
0
Not used
4
0
Not used
3
0
Not used
2
0
Not used
1
0
Not used
0
0
Unique Switch 94 - for RS-232C interface
Initial
Switch
Setting
Adjusts CI counter
7
0
6
1
5
0
4
1
3
0
Factory use only
2
0
Factory use only
Fax reception while scanning
or printing through the RS-
1
0
232C
0: No
1: Yes
0
0
Factory use only
Adjust
Adjust
If the remote fax machine disconnects the phone
line before the PC responds to the CI signal, the
fax regards that the PC is off and then it will receive
the next call.
In this case, increase the CI counter to be more
than the number of rings the PC receives.
Switch 3210
To reset this status, first initialise the PC's fax
software and then the fax machine (press MENU,
6, 1, 0, 2, ENTER; see operating instructions for
more detail).
Determines if the unit rejects fax reception or
receivies it while the PC scans or prints through the
RS-232C.
3-97
Usage/Comments
Usage/Comments
CI counter
0000
0 time
0001
1 time
0010
2 times
:
5 times ← Initial setting
0101
:
1110
14 times
1111
15 times