Muratec F-360 Field Engineering Manual page 70

Facsimile system
Hide thumbs Also See for F-360:
Table of Contents

Advertisement

Memory Switch 63 - Remote reception and TAD interface
Initial
Switch
Setting
Adjust silent detection time
7
0
6
1
5
0
4
1
Number of seconds silent
detection remains active
3
0
2
1
1
1
0
0
Adjust
This switch adjusts the length of silence required
for silent detection activation.
Switch 7 6 5 4
This switch adjusts the length of time silence
detection remains active.
Switch 3 2 1 0
3-45
Usage/Comments
Time
0 0 0 0
0 sec
0 0 0 1
1 sec
0 0 1 0
2 sec
0 0 1 1
3 sec
0 1 0 0
4 sec
0 1 0 1
5 sec
Initial setting
0 1 1 0
6 sec
0 1 1 1
7 sec
1 0 0 0
8 sec
1 0 0 1
9 sec
1 0 1 0
10 sec
1 0 1 1
11 sec
1 1 0 0
12 sec
1 1 0 1
13 sec
1 1 1 0
14 sec
1 1 1 1
15 sec
Time
0 0 0 0
0 sec
0 0 0 1
10 sec
0 0 1 0
20 sec
0 0 1 1
30 sec
0 1 0 0
40 sec
0 1 0 1
50 sec
0 1 1 0
60 sec
Initial setting
0 1 1 1
70 sec
1 0 0 0
80 sec
1 0 0 1
90 sec
1 0 1 0
100 sec
1 0 1 1
110 sec
1 1 0 0
120 sec
1 1 0 1
130 sec
1 1 1 0
140 sec
1 1 1 1
150 sec

Advertisement

Table of Contents
loading

Table of Contents