Muratec F-360 Field Engineering Manual page 34

Facsimile system
Hide thumbs Also See for F-360:
Table of Contents

Advertisement

Machine Parameter 12
Initial
Switch
Setting
ADF scanner registration
7
0
adjustment (Horizontal)
Adjusts the start point to scan
the document.
6
0
The plus setting increases
the left margin and the minus
setting decreases it.
5
0
Each setting changes by
0.5 mm.
4
0
3
0
2
0
1
1
0
0
Machine Parameter 13
Initial
Switch
Setting
Not used
7
0
Not used
6
0
Not used
5
0
Not used
4
0
Not used
3
0
Not used
2
0
Not used
1
0
Not used
0
0
Adjust
Switch 76543210
Adjust
3-9
Usage/Comments
Settings
00000111
3.5 mm
00000110
3.0 mm
00000101
2.5 mm
00000100
2.0 mm
00000011
1.5 mm
00000010
1.0 mm
00000001
0.5 mm
00000000 Standard
10000001
-0.5 mm
10000010
-1.0 mm
10000011
-1.5 mm
10000100
-2.0 mm
10000101
-2.5 mm
10000110
-3.0 mm
10000111
-3.5 mm
Usage/Comments
Maximum
← Initial setting
Minimum