● Code : L-1
● Symptom :
-. Horizontal White Line(s)
-. Horizontal Sharp Line(s) for a Particular Color
-. Horizontal Sharp Line(s) for Multiple Colors of 78mm Gap
● Possible Cause:
1. Gear defect , OPC defect
2. High voltage section defect
● Troubleshooting method :
[step1] Gear defect , OPC defect
If the horizontal line defect occurs at regular intervals, refer to
Roller' on page 4-209.
defective
Refer to the defect period table and replace the defective part.
[step2] High voltage section defect
1) If the horizontal line occurs randomly, take out the imaging unit and re-install it again.
2) If the problem persists, check the high voltage contact point.
.