NVM Description
Code
(GUI)
109-090 Cardstock Temperature
offset
109-100 Envelopes Temperature
offset
109-110 Labels Temperature
offset
109-120 Fuser Bias Duty
109-130 Thick Temperature
Offset
110-000 LD Power Yellow(Half)
110-010 LD Power Magenta(Half)
110-020 LD Power Cyan(Half)
110-030 LD Power Black(Half)
Service Manual
Troubleshooting
Max
Default
/ Min
7
14/0
* Fusing temperature variableness of Cardstock type paper
* Default temperature : 150 ℃
* Range of variableness : 157 ~ 143℃ (150℃ +/- 7℃)
* In case, the value is more than 7 :
The fuser temperature increases (input value-7)℃ than 150℃
* In case, the value is less than 7 :
The fuser temperature decreases (7-input value)℃ than 150℃
7
14/0
* Fusing temperature variableness of Envelope type paper
* Range of variableness : 157 ~ 143℃ (150℃ +/- 7℃)
* In case, the value is more than 7 :
The fuser temperature increases (input value-7)℃ than 150℃
* In case, the value is less than 7 :
The fuser temperature decreases (7-input value)℃ than 150℃
7
14/0
* Fusing temperature variableness of Label type paper
* Default temperature : 150℃
* Range of variableness : 157 ~ 143℃ (150℃ +/- 7℃)
* In case, the value is more than 7 :
The fuser temperature increases (input value-7)℃ than 150℃
* In case, the value is less than 7 :
The fuser temperature decreases (7-input value)℃ than 150℃
154
194/154 * Fuser Bias PWM
* Read only
* You can't chage this value. ( HH condition : 194 / Other : 154 )
7
14/0
* Fusing temperature variableness of Label type paper
* Default temperature : 150℃
* Range of variableness : 157 ~ 143℃ (150℃ +/- 7℃)
* In case, the value is more than 7 :
The fuser temperature increases (input value-7)℃ than 150℃
* In case, the value is less than 7 :
The fuser temperature decreases (7-input value)℃ than 150℃
88
250/10 * This PWM sets the laser intensity to be shoot on OPC.
(This value is used at half speed that the process speed of OPC
88
250 /10
is the half of normal condition )
88
250 /10
* Default 88 PWM is approximately 0.223mW.
88
250 /10
* This value changes +0.0026mw per +1 PWM.
* This value is to check the normal state of HVPS,LSU.
* The value set on EDC manually is not applied to the real printing.
* At real printing, the value is applied by the Look-Up Table
considering the environment and life automatically.