Samsung CLX-8540ND Service Manual page 213

Digital color laser mfp
Hide thumbs Also See for CLX-8540ND:
Table of Contents

Advertisement

Code
Displayed Name
107-100
iTHV(-) Bias
107-110
Detach Bias
107-170
Saw Bias
109-000
Fuser Temperature A
109-010
Fuser Temperature B
109-030
Fuser Motor Forward
109-110
Fuser Crum Read1
109-120
Fuser Crum Read2
109-150
Fuser Bias(+) Bias
109-151
Fuser Bias(-) Bias
110-000
LSU Motor1 Run Ready
110-010
LSU Motor2 Run Ready
110-020
LSU Fan1 Run Ready
110-040
LSU Clean Motor
110-050
LSU Clean Sensor
110-060
LSU Motor1 Run
110-070
LSU Motor2 Run
110-080
LSU LD Power1
110-090
LSU LD Power2
110-100
LSU LD Power3
110-110
LSU LD Power4
110-120
LSU Fan1 Run
111-000
Toner Dispense Motor Yellow
Toner Dispense Motor
111-010
Magenta
111-020
Toner Dispense Motor Cyan
111-030
Toner Dispense Motor Black
111-040
Toner Sensor Yellow
111-050
Toner Sensor Magenta
111-060
Toner Sensor Cyan
111-070
Toner Sensor Black
111-100
ID Sensor(Vo1/S) Check
111-110
ID Sensor(Vo2/P) Check
113-000
Finisher Present Sensor
113-010
Entrance Motor
113-020
Exit Motor
113-030
Paddle Motor
113-040
Front Jog Home
Service Manual
Troubleshooting
Meaning
iTHV minus bias voltage on at normal drive level
Detack bias voltage on at normal drive level
Saw bias voltage on at normal drive level
Detects what the temperature A is on fuser.
Detects what the temperature B is on fuser.
Fuser Motor Forward On/Off
Detect if the life of fuser1 is exhausted.
Detect if the life of fuser2 is exhausted.
Fuser Positive bias voltage on at normal drive level
Fuser Negative bias voltage on at normal drive level
Detects if LSU motor1 runs at normal speed.
Detects if LSU motor2 runs at normal speed.
Detects if LSU Fan Motor runs at normal speed.
Detect if the LSU Clean Motor On/Off
Detect if the LSU Clean Motor is On or Off
LSU Motor1 On/Off
LSU Motor2 On/Off
LSU LD1 Power On/Off (yellow)
LSU LD2 Power On/Off (magenta)
LSU LD3 Power On/Off (cyan)
LSU LD4 Power On/Off (black)
Start/Stop LSU Fan Run
Toner Dispense(Supply) Motor On/Off
Toner Dispense(Supply) Motor On/Off
Toner Dispense(Supply) Motor On/Off
Toner Dispense(Supply) Motor On/Off
TC sensor in developer tank.
TC sensor in developer tank.
TC sensor in developer tank.
TC sensor in developer tank.
Display ID Sensor(Vo1,S) reading value
Display ID Sensor(Vo2,P) reading value
Detect if the Finisher is in place.
Entrance Motor run as IOT Speed <about 5 sec>
Exit Motor run as IOT Speed <about 5 sec>
Paddling
Front Jogger move Home
4-51
Input /
State
Output
Displayed
Output
On[Off]
Output
On[Off]
Output
On[Off]
Input
Numeric 3 digits
Input
Numeric 3 digits
Output
On[Off]
Input
High[Low]
Input
High[Low]
Output
On[Off]
Output
On[Off]
Input
High[Low]
Input
High[Low]
Input
High[Low]
Output
High[Low]
Input
High[Low]
Output
On[Off]
Output
On[Off]
Output
On[Off]
Output
On[Off]
Output
On[Off]
Output
On[Off]
Output
On[Off]
Output
On[Off]
Output
On[Off]
Output
On[Off]
Output
On[Off]
Input
Numeric 3 digits
Input
Numeric 3 digits
Input
Numeric 3 digits
Input
Numeric 3 digits
Input
Numeric 4 digits
Input
Numeric 4 digits
Input
Install[Not Install]
Output
On[Off]
Output
On[Off]
Output
On
Output
On
Samsung Electronics