Alarms - Comtech EF Data CDM-625A Installation And Operation Manual

Advanced satellite modem (18 kbps – 25 mbps)
Hide thumbs Also See for CDM-625A:
Table of Contents

Advertisement

CDM-625A Advanced Satellite Modem
CDM-625A ODU (Transceiver, BUC, LNB) Operation
10.3.3.3.3.1.3.1
Current Status:
This screen is read-only. Press ENTER or CLEAR to return to the previous menu.
10.3.3.3.3.1.3.2
As stored events are compiled, the screen shows:
Reading Stored Faults..... Please Wait
Once the events are compiled, the Stored Alarms screen appears as shown here:
Stored Alarms:
IF #84: 10/14/04
Use the
◄ ►
arrow keys to select between the log entries and the Clear-All option.
To view a log entry: With the cursor on the entry number, use the
through the entries. Up to 99 entries are stored. Each entry provides the following information:
Item
Entry type
Entry number
Date
Time
Description of information / fault
To clear the Stored Alarms Log, use the
arrow keys to select Yes. Press ENTER to clear the log.
▲▼
ODU: FSK-control  CSAT (2CSATs  CSAT #X) 
Alarms Current-Alarms
Power-Supply = OK
ODU: FSK-control  CSAT (2CSATs  CSAT #X) 
Alarms  Stored-Alarms
Clear-All: No
Comments
00 through 99
European Day-Month-Year (DD-MM-YY) format
Hour:Minute:Second (HH:MM:SS) format
Example: Power On
Tx = OK
Rx = OK
Misc = OK
(No,Yes)
12:52:08
Power On
IF = Information
FT = Fault
OK = Fault cleared
◄ ►
arrow keys to select Clear-All, and then use the
10–19
Revision 0
MN-CDM625A
arrow keys to view
▲▼

Advertisement

Table of Contents
loading

Table of Contents