Installing Into A Rack Enclosure - Comtech EF Data CDM-625A Installation And Operation Manual

Advanced satellite modem (18 kbps – 25 mbps)
Hide thumbs Also See for CDM-625A:
Table of Contents

Advertisement

CDM-625A Advanced Satellite Modem
Installation
As shown in Figure 2-1: Once opened, inspect the shipment:
Step
Task
1
Keep all shipping materials for storage or reshipment.
2
Check the packing list to ensure the shipment is complete.
Inspect the equipment for any possible damage incurred during shipment.
3
Contact the carrier and Comtech EF Data Product Support immediately and submit a
damage report if damage is evident to the shipment.
4
Review the manual carefully to become familiar with operation.
5
Proceed to Sect. 2.2 Installing and Mounting the CDM-625A.
2.2

Installing Into a Rack Enclosure

When mounting the CDM-625A into a rack enclosure (Figure 2-1):
PROPER GROUNDING PROTECTION IS REQUIRED. The equipment must be
connected to the protective earth connection at all times. It is therefore imperative
that the unit is properly grounded, using the ground stud provided on the unit rear
panel, during installation, configuration, and operation.
PROPER AIR VENTILATION IS REQUIRED. In a rack system where there is high
heat discharge, provide forced-air cooling with top- or bottom-mounted fans or
blowers.
For information about custom rack enclosures, contact Comtech EF Data Product
Support or visit Comtech EF Data's Web site (www.comtechefdata.com).
The CDM-625A CANNOT have rack slides mounted to the sides of the chassis.
In Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun
pistorasiaan."
In Norway: "Apparatet må tilkoples jordet stikkontakt."
In Sweden: "Apparaten skall anslutas till jordat uttag."
o Make sure there is adequate clearance inside the enclosure, especially at
the side for air ventilation.
o Air temperature inside the rack enclosure should
°
(122
F).
2–2
Revision 0
MN-CDM625A
°
never
exceed 50
C