IQ DISPLAY MODULE (IQDM) AND IQDM-P
DIAGNOSTICS: EXCEL SYSTEM
ODOMETER
Displays approximate distance travelled in miles.
VEHICLE SPEEDS (IQDM-P ONLY)
Press right arrow to display programmed speeds for each speed setting. See Code A, Code B, and Code C on
page 23-4.
PEDAL COUNTERS
Accumulates accelerator pedal usage.
FAULT COUNTERS
The Fault Counters indicate how many times each fault type has been recorded since the last clearing of fault history.
See following Faults Menu section.
FAULT COUNT ODOMETERS
The Fault Count Odometers indicate the odometer reading associated with the last occurrence of each fault type. Will
indicate 0.0 (miles) if the fault occurred before the last clearing of fault history.
NEG IA 250
Displays how many, or the last time, the armature current reached 250 amps during regenerative braking (version 13
or newer software).
NEG IA 300
Displays how many, or the last time, the armature current reached 300 amps during regenerative braking (version 13
or newer software).