Battery Testing - 8 Volt; Battery Charger Test; On-Charge Voltage Test; Hydrometer Test - Club Car 2009-20011 Electric Precedent Maintenance And Service Manual

Iq system and excel system vehicles
Table of Contents

Advertisement

BATTERIES
BATTERY TESTING – 8 VOLT
See General Warnings on page 1-1.
Four tests have been developed to help diagnose problems with batteries that have not performed as expected.
Because each test becomes progressively more detailed and time-consuming, begin with the first test and follow
through with the other tests until the problem has been identified as outlined in the Battery Troubleshooting Chart
(Figure 18-1, Page 18-2).

BATTERY CHARGER TEST

The easiest way to monitor the condition of a vehicle's batteries is simply to observe the reading on the battery charger
ammeter at the end of the charge cycle. After a full charge, disconnect the charger DC plug, wait 20 to 30 seconds and
reconnect the charger DC plug. The ammeter needle will jump to 15 amps or more and then taper to below 6 amps
within 10 to 20 minutes, indicating sound, fully charged batteries.
Continued poor performance may indicate a problem in the vehicle electrical system, brakes or battery charger. If the
problem is not found in the vehicle or charging system, proceed to the on-charge voltage test. Batteries that remain at
8 amps or higher should be tested further using the on-charge voltage test.

ON-CHARGE VOLTAGE TEST

When the batteries are fully charged, disconnect the charger DC plug. Wait 20 to 30 seconds and reconnect the DC
plug to restart the charger. After 5 minutes, use a multimeter to check and record the voltage of the battery set as
well as the individual batteries. Set the multimeter to 200 volts DC. Place the red (+) probe on the positive (+) post of
battery no. 1 and the black (–) probe on the negative (–) post of battery no. 6. Record reading. Then set multimeter to
20 volts DC and place the red (+) probe on the positive (+) post and the black (–) probe at the negative (–) post of
each battery. Record the readings.
The on-charge voltage for the set should be between 56.0 volts and 63.0 volts depending on the age and state of
charge of the batteries being tested. If individual batteries read above 7.0 volts and are within 0.5 volts of each
other, go to the hydrometer test. If any battery reads below 7.0 volts and not within 0.5 volts of those batteries
above 7.0 volts, replace battery. If readings are below 7.0 volts but within 0.5 volts of each other, the batteries are
old. Old batteries may have enough capacity left to last several more months. Go to hydrometer test. See Battery
Troubleshooting Chart on page 18-2 and the examples on the following pages.

HYDROMETER TEST

A hydrometer measures the specific gravity of the battery's electrolyte. The higher the specific gravity, the higher the
state of charge of the batteries. A fully charged battery should read between 1.250 and 1.280 at 80 °F (26.7 °C). Never
add acid to batteries to obtain a higher specific gravity.
Performing the Hydrometer Test
1.
Be sure batteries have sufficient electrolyte to cover plates by approximately 1/2 inch (13 mm) and are fully
charged prior to beginning test. If water must be added, recharge the batteries before performing the hydrometer
test. See following CAUTION.