SERVICE PROGRAM TABLES
2180
Lens Temp
These SPs display the measured temperatures of the optical lenses for each color.
001 M-K
002 Y-C
2181
Alignment Result
These SPs display the amount of shift correction for each color, the amount of
correction done at each sensor in both the main scan and sub scan direction.
[-2000~+2000/1]
001 M Skew Amt
002 M Main Skew 1
003 M Main Skew 2
004 M Main Skew 3
005 M Sub Skew 1
006 M Sub Skew 2
007 M Sub Skew 3
011 C Skew Amt
012 C Main Skew 1
013 C Main Skew 2
014 C Main Skew 3
015 C Sub Skew 1
016 C Sub Skew 2
017 C Sub Skew 3
021 Y Skew Amt
022 Y Main Skew 1
023 Y Main Skew 2
024 Y Main Skew 3
025 Y Sub Skew 1
026 Y Sub Skew 2
Lens Temperature Monitor
Displays the measured temperature of the magenta and
black lenses (in the laser optics).
[0~999/0.1 deg]
Displays the measured temperature of the yellow and
cyan lenses (in the laser optics).
[0~999/0.1 deg]
Position Alignment Result
The amount of skew correction for magenta.
Amount of shift correction for magenta in the main scan
direction at sensor 1.
Amount of shift correction for magenta in the main scan
direction at sensor 2.
Amount of shift correction for magenta in the main scan
direction at sensor 3.
Amount of shift correction for magenta in the sub scan
direction at sensor 1.
Amount of shift correction for magenta in the sub scan
direction at sensor 2.
Amount of shift correction for magenta in the sub scan
direction at sensor 3.
The amount of skew correction for cyan.
Amount of shift correction for cyan in the main scan
direction at sensor 1.
Amount of shift correction for cyan in the main scan
direction at sensor 2.
Amount of shift correction for cyan in the main scan
direction at sensor 3.
Amount of shift correction for cyan in the sub scan
direction at sensor 1.
Amount of shift correction for cyan in the sub scan
direction at sensor 2.
Amount of shift correction for cyan in the sub scan
direction at sensor 3.
The amount of skew correction for yellow.
Amount of shift correction for yellow in the main scan
direction at sensor 1.
Amount of shift correction for yellow in the main scan
direction at sensor 2.
Amount of shift correction for yellow in the main scan
direction at sensor 3.
Amount of shift correction for yellow in the sub scan
direction at sensor 1.
Amount of shift correction for yellow in the sub scan
direction at sensor 2.