SERVICE PROGRAM TABLES

Group 4000

4008
Sub Scan Mag
Adjusts the sub-scan magnification by changing the scanner motor speed.
[-10~+10/0.1%]
4010
Sub Scan Reg
Adjusts the leading edge registration by changing the scanning start timing in the sub-
scan direction.
[-30~+30/0.1 mm]
4011
Main Scan Reg
Adjusts the side-to-side registration by changing the scanning start timing in the main
scan direction.
Note: This adjustment is done for the ADF with SP6006 (ADF Reg. Adj.).
[-25~+25/0.1 mm]
4012
Set Scale Mask
Sets the blank margin at each side for erasing the original shadow caused by the gap
between the original and the scale. This can be done for both scanning on the
exposure glass (book mode) and the ADF (ADF) for the leading and trailing edges.
001 Book:Sub LEdge
002 Book:Sub TEdge
003 Book:Main:LEdge
004 Book:Main:TEdge
005 ADF:Sub:LEdge
007 ADF:Main:LEdge
008 ADF:Main:TEdge
4013
Scan Free Run
Performs the scanner free run with the exposure lamp ON or OFF for full-color, full
size (A3 or DLT).
001 Lamp:OFF
002 Lamp:ON
4014
Scan
These SPs enable/disable detection of the scanner at its home position.
001 Enable
Enables detection of the scanner at its home position.
002 Disable
Disables detection of the scanner at its home position.
Sub Scan Magnification Adjustment
Sub Scan Registration Adjustment
Main Scan Registration Adjustment
Set Mask for Scale Edge
[0~30/0.1 mm]
Free Run: Scanner
[0~1/1] 0:Off, 1:On
Execute Scan DFU
5-96