SERVICE PROGRAM TABLES
4646 Scan Auto Error
This SP sets the error flag to display as the SBU is updated automatically when the
machine is switched ON.
001 Gain
[0x00~0xFFFF]
002 K Level
b7
GAIN_ERR_BO
b6
GAIN_ERR_BE
b5
GAIN_ERR_BK_GO
b4
GAIN_ERR_BK_GE
b3
GAIN_ERR_GO
b2
GAIN_ERR_GE
b1
GAIN_ERR_RO
b0
GAIN_ERR_RE
4647 HW Error Flag
This SP sets the error flag to confirm machine ON processing when the machine is
switched ON.
[0x00~0x3F]
4680 Fact Gain Adj:R
When switched ON, this SP displays the setting done at the factory for RED O
(ODD) and E (EVEN) gain in the ASCI on the SBU after white level adjustment every
time the machine is switched ON.
001 RE
[0~1023/1]
002 RO
4681 Fact Gain Adj:G
When switched ON, this SP displays the setting done at the factory for GREEN and
black-and-white O (ODD) and E (EVEN) gain in the ASCI on the SBU after white
level adjustment every time the machine is switched ON.
001 Color:GE
002 Color:GO
005 B/W:GE
006 B/W:GO
4682 Fact Gain Adj:B
When switched ON, this SP displays the setting done at the factory for BLUE O
(ODD) and E (EVEN) gain in the ASCI on the SBU after white level adjustment every
time the machine is switched ON.
001 BE
[0~1023/1]
002 BO
4690 White Lvl Peak:R
When switched ON, these SP codes display E (EVEN) or O (ODD) for the white
level peak RED data after white level detection (AGC) after the machine is switched
ON.
001 RE
002 RO
Error Flag for Automatic Adjustment: Scanning DFU
Hardware Error Flag Adjustment: Scanning DFU
Factory Gain Adjustment at Factory: Red DFU
Factory Gain Adjustment at Factory: Green DFU
[0~1023/1]
Factory Gain Adjustment at Factory: Blue DFU
White Level Peak: Red Scan Data DFU
[0~255/1]
5-102