PROCESS CONTROL
Adjust Vpl
The LD power is adjusted in order to get to the target Vpl (the Vpl value after
correction for Vr)
After correction for Vr, the value of Vpl must be within 5V.
Vpl (LD Power) Adjust Errors
SC Codes
SP3821 Procon OK?
SC424~SC427
Vtref/Vtcnt Calibration
Vtref calibration:
Vtcnt calibration:
This lets the machine use the results of the process control calculations to get the
correct toner amount.
There is no check for abnormal conditions at this step.
Process Control Gamma Correction
The following adjustments are done, based on the development gamma correction,
to achieve the target values (Vd , Vl , Vb )
To adjust Vd (drum bias), the voltage of the charge roller is raised.
To adjust Vl (laser power), the input current of the laser diodes is raised.
To adjust Vb (development bias), the charge on the development roller is
increased.
At this time:
Development gamma must be in the range 0.3 to 6.0.
Development start voltage must be in the range –150 to 150 V.
Potential Control Errors
SC Codes
SC410~SC417
See "Process Control Troubleshooting" in Section "4. Troubleshooting".
64
Calibrates Vtref to the value of Vt
If Vt is not within the range of 2 to 3 V, Vtcnt is changed to
bring it within this range.
For More Details:
See "Process Control Troubleshooting" in
Section "4. Troubleshooting".
For More Details:
6-86