Adjusting The Nip Width: - Toshiba e-STUDIO4500c Service Manual

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO4500c:
Table of Contents

Advertisement

ADDITIONAL INFORMATIONS

ADJUSTING THE NIP WIDTH:

1. Remove the fusing unit from the copier and place it on the table.
2. Make sure the pressure levers ([I], [J]) are in the upper position as shown in
Photo A.
NOTE: If the levers are not in the upper position, pressure will not be applied
between the fusing belt and pressure roller.
Photo A: OK
[I]
3. Turn screws [G] and [H] to bring the nip width to within specification.
To increase the nip width, turn the screws clockwise.
To decrease the nip width, turn the screws counter-clockwise.
NOTE: One turn of the screw changes the nip width about 0.3mm.
Clockwise direction
[G]
[J]
[G]
4-114
07/04
[H]
Photo B: NG
[I]
Clockwise direction
[H]
April 2007
[J]