After Replacing The Pcu Components And Developer - Toshiba e-STUDIO4500c Service Manual

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO4500c:
Table of Contents

Advertisement

August, 2006
3.5.7 AFTER REPLACING THE PCU COMPONENTS AND
DEVELOPER
Do the following procedure after you replace the PCU, development, or any related
parts. Pay attention to the combination of replaced parts in the table below (require
procedures are different). Any SPs described in this table should be performed
according to the steps below.
1. Open the front door, then turn on the main power.
2. After the "Open Cover" message is shown on the display, close the front door.
3. Do the required SP.
Combination of Replaced Parts
No.
Drum
Developer
1
2
3
4
5
6
7
8
9
10
Drum
Drum
Cleaning
Cleaning
Blade
Brush
3-57
PCU (PHOTOCONDUCTOR UNITS)
Required SPs
After
Replacement
SP3820 002
Before reinstallation, cover the
(Manual Procon)
drum completely with Lubricant
Powder.
SP3810 001-005
Do NOT do these SPs which
(ClngInitSetExe)
initialize the TD sensor:
-and-
SP3801 001 to 006
SP3820 002
SP3811 001 to 006
(Manual Procon)
SP3801 001-006
Before reinstallation, cover the
(Init TD Sensor)
drum completely with Lubricant
Powder. Do these SPs to
initialize the TD sensor only for
the color(s) that were replaced.
SP3811 001-006
Before reinstallation, cover the
(Dev Setup Exe)
drum completely with Lubricant
Powder.
Do these SPs to initialize the
developer only for the color(s)
that were replaced.
SP3801 001-006
Do these SPs to initialize the TD
(Init TD Sensor)
sensor only for the color(s) that
were replaced.
SP3811 001-006
Do these SPs to initialize the
(Dev Setup Exe)
developer only for the color(s)
that were replaced.