Toshiba e-STUDIO4500c Service Manual page 607

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO4500c:
Table of Contents

Advertisement

August, 2006
5816
Remote Service (Not Used)
001
I/F Setting
002
CE Call
003
Function Flag
006
Device
Information Call
Display
007
SSL Disable
008
RCG Connect
Timeout
009
RCG Write to
Timeout
010
RCG Read
Timeout
011
Port 80 Enable
Turns the remote diagnostics off and on.
[0~2/1]
0: Remote diagnostics off.
1: Serial (CSS or NRS) remote diagnostics on.
2: Network remote diagnostics.
Lets the service engineer start or end the remote machine
check with CSS or NRS; to do this, press the center report
key.
Enables and disables remote diagnosis over the NRS
network.
[0~1/1]
0: Disables remote diagnosis over the network.
1: Enables remote diagnosis over the network.
Controls if the item for initial setting of the screen for the NRS
device-information notification-call is shown.
[0~1/1]
0: Enabled. Item initial setting not shown.
1: Disable. Item for initial setting shown.
Controls if RCG (Remote Communication Gate) confirmation
is done by SSL during an RCG send for the NRS over a
network interface.
[0~1/1]
0: Yes. SSL not used.
1: No. SSL used.
Sets the length of time (seconds) for the time-out when the
RCG (Remote Communication Gate) connects during a call
via the NRS network.
[1~90/1 sec.]
Sets the length of time (seconds) for the time-out when sent
data is written to the RCG during a call over the NRS
network.
[0~100/1 sec.]
Sets the length of time (seconds) for the timeout when sent
data is written from the RCG during a call over the NRS
network.
[0~100/1 sec.]
Controls if permission is given to get access to the SOAP
method over Port 80 on the NRS network.
[0~1/1]
0: No. Access denied
1: Yes. Access granted.
5-115
SERVICE PROGRAM TABLES

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio5500cE-studio 4500cE-studio 5500c

Table of Contents