8. Slowly and carefully pull the image transfer unit [A] out of the machine.
Important!
Remove carefully. The image
transfer unit is heavy and not
attached to the rails with screws.
To prevent toner scattering inside
and outside the unit, keep the unit [B]
flat when you remove it, lift it, carry it,
and put it down.
Never stand the image transfer unit
[C] on its edge before you remove
the cleaning unit from the ITB (
3.8.1).
Never place the image transfer unit
on a carpet where toner may scatter
or the unit will collect dust.
Reinstallation
Re-insert the image transfer unit slowly and carefully to avoid snagging the belt
on the frame of the machine.
Make sure that the image transfer unit does not snag on the toner cap of the
yellow PCU on the far left.