August, 2006
[E]
5. Remove the PCU motor [A] (
6. Open the front door.
7. Remove the toner hopper. ( 3.2.7)
Important: Make sure the toner hopper slide rails are pushed into the machine.
8. At the front of the machine, attach the short tool [B] to the shaft of the drum
motor to be removed.
9. Rotate the short tool in the direction of the embossed arrow [C] on the short
tool (counter-clockwise) until the holes are aligned.
NOTE: You must fasten the short tool.
10. Use the M3x9 screw to fasten the screws to lock the shaft [D].
11. Remove the drum motor screws [E] (
12. Turn the drum-motor hub [F] counter-clockwise
shaft.
13. Remove the drum motor
Reinstallation
1. Attach the short tool to the drum shaft and fasten it with the screw.
2. Attach the drum motor.
3. Rotate the drum motor clockwise until it stops.
4. Fasten the three screws to the drum motor.
[A]
[F]
x1,
(
x1)
3-147
[C]
x4).
x3)
and remove the drum motor