REPLACEMENT AND ADJUSTMENT

3.2.3 ALIGNMENT BRUSH ROLLER

[B]
[D]
B478R507.WMF
1. Open the front door and pull out the staple unit.
2. Remove the rear cover.
3. Remove the main board and all connectors (
4. Remove the screw [A] and tension spring [B] for the tension bracket [C], and
release the tension of the timing belt.
5. Remove the pulley [D] and bushing [E] (
6. Remove the inner cover [F] (
7. Open the guide [G], then remove the alignment brush roller assembly [H] (
1).
8. Remove the alignment brush roller [I] (
[C]
[A]
[E]
[H]
[I]
x 2).
x 1).
x 1, bushing x 1 front/back).
B706-8
06/09
September 2006
B478R508.WMF
x 8).
[G]
[F]
x