COPIER E-STUDIO4500C/5500C
[E]
5. On the front end of the PCU, remove the shaft cap [A] and lock plate [B] (
Important: After you remove the shaft cap, make sure that you do not turn the
shaft [C] of the development roller.
6. On the rear end of the PCU, remove the lock plate [D] (
7. Remove the development unit [E] from the PCU.
[D]
1-16
August, 2006
[B]
[C]
B132R210.WMF
x 4).
[A]
x 3).