Sc900: Miscellaneous - Toshiba e-STUDIO4500c Service Manual

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO4500c:
Table of Contents

Advertisement

April, 2007

SC900: Miscellaneous

SC900
D
Electrical total counter error
The total counter contains
something that is not a number.
SC910
B
SC911
SC912
SC913
SC914
B
SC919
D
External controller (E-7000) down
The EAC received an interrupt signal
from the FLUTE serial driver during
print jobs in progress and the
connection between the copier and
external controller (E-7000) was
broken.
Note: The EAC is the External Api
Converter.
SC920
B
Printer error 1
An internal application error was
detected and operation cannot
continue.
SC921
B
Printer error 2
When the application started, the
necessary font was not on the SD
card.
External controller (E-7000) error 1
External controller (E-7000) error 2
External controller (E-7000) error 3
External controller (E-7000) error 4
The external controller (E-7000) sends
an error message.
External controller (E-7000) error 5
The external controller (E-7000) sends
an error message.
SERVICE CALL CONDITIONS
NVRAM incorrect type
NVRAM defective
NVRAM data scrambled
Unexpected error from external source
Turn the machine power
OFF/ON
Switch the machine OFF and ON.
Software defective; turn the machine
OFF/ON, or change the controller
firmware
Insufficient memory
Font not on the SC card
4-71
Turn the machine power
OFF/ON

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio5500cE-studio 4500cE-studio 5500c

Table of Contents