:POWer:SIGNals:OVERshoot
Command Syntax
:POWer:SIGNals:OVERshoot <percent>
<percent> ::= percent of overshoot value in NR1 format
The :POWer:SIGNals:OVERshoot command specifies the percent of
overshoot of the output voltage. This value is used to determine the
settling band value for the transient response and to adjust the vertical
scale of the oscilloscope.
Query Syntax
:POWer:SIGNals:OVERshoot?
The :POWer:SIGNals:OVERshoot query returns the overshoot percent
setting.
Return Format
<percent><NL>
<percent> ::= percent of overshoot value in NR1 format
See Also
•
•
•
•
•
•
•
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
(see
page
1208)
":POWer:TRANsient:APPLy"
":POWer:SIGNals:AUTosetup"
":POWer:SIGNals:DURation:TRANsient"
":POWer:SIGNals:IEXPected"
":POWer:SIGNals:VSTeady:TRANsient"
":POWer:SIGNals:SOURce:CURRent<i>"
":POWer:SIGNals:SOURce:VOLTage<i>"
on page 608
on page 581
on page 589
on page 590
on page 597
on page 598
on page 599
25
:POWer Commands
591