:SBUS<n>:FLEXray:TRIGger
Command Syntax
:SBUS<n>:FLEXray:TRIGger <condition>
<condition> ::= {FRAMe | ERRor | EVENt}
The :SBUS<n>:FLEXray:TRIGger:TRIGger command sets the FLEXray
trigger on condition:
• FRAMe — triggers on specified frames (without errors).
• ERRor — triggers on selected active error frames and unknown bus
• EVENt — triggers on specified FlexRay event/symbol.
Query Syntax
:SBUS<n>:FLEXray:TRIGger?
The :SBUS<n>:FLEXray:TRIGger? query returns the current FLEXray
trigger on condition.
Return Format
<condition><NL>
<condition> ::= {FRAM | ERR | EVEN}
See Also
•
•
•
•
•
•
•
•
•
•
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
(see
page
1208)
conditions.
"Introduction to :TRIGger Commands"
":TRIGger:MODE"
on page 944
":SBUS<n>:FLEXray:TRIGger:ERRor:TYPE"
":SBUS<n>:FLEXray:TRIGger:EVENt:AUToset"
":SBUS<n>:FLEXray:TRIGger:EVENt:BSS:ID"
":SBUS<n>:FLEXray:TRIGger:EVENt:TYPE"
":SBUS<n>:FLEXray:TRIGger:FRAMe:CCBase"
":SBUS<n>:FLEXray:TRIGger:FRAMe:CCRepetition"
":SBUS<n>:FLEXray:TRIGger:FRAMe:ID"
":SBUS<n>:FLEXray:TRIGger:FRAMe:TYPE"
:SBUS<n> Commands
on page 935
on page 696
on page 697
on page 698
on page 699
on page 700
on page 701
on page 702
on page 703
28