4
Commands Quick Reference
Table 55 :TRIGger:GLITch Commands Summary (continued)
Command
:TRIGger:GLITch:RANGe
<less_than_time>[suff
ix],
<greater_than_time>[s
uffix] (see
page
:TRIGger:GLITch:SOURc
e <source> (see
page
974)
Table 56 :TRIGger:OR Commands Summary
Command
:TRIGger:OR <string>
(see
page
976)
146
Query
:TRIGger:GLITch:RANGe
? (see
page
973)
:TRIGger:GLITch:SOURc
e? (see
page
Query
:TRIGger:OR? (see
page
976)
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
Options and Query Returns
<less_than_time> ::= 15 ns to
973)
10 seconds in NR3 format
<greater_than_time> ::= 10 ns to
9.99 seconds in NR3 format
[suffix] ::= {s | ms | us | ns |
ps}
<source> ::= {CHANnel<n> |
974)
DIGital<d>}
<n> ::= 1 to (# analog channels)
in NR1 format
<d> ::= 0 to (# digital channels
- 1) in NR1 format
Options and Query Returns
<string> ::= "nn...n" where n ::=
{R | F | E | X}
R = rising edge, F = falling
edge, E = either edge, X = don't
care.
Each character in the string is
for an analog or digital channel
as shown on the front panel
display.