Table 5. SPCN Error Codes (continued)
Error Code
1011 9116

Firmware Error Codes

Attention:
corrected, go to "MAP 1540: Minimum Configuration" on page 57 unless otherwise
indicated in the tables.
If you replace FRUs or perform an action and the problem is corrected, go to "MAP
410: Repair Checkout" in RS/6000 and Eserver pSeries Diagnostic Information for
Multiple Bus Systems.
Note: Do not shut down the system if the FRU was replaced by hot swap.
Table 6. Firmware Error Codes
Error Code
2011 0xxx
2011 031y
2022 0000
Description
SPCN communication failure with
operator panel
If you replace FRUs or perform an action and the problem is still not
Description
Power supply
Power supply failure
RIO bus running slow
Action/ Possible Failing FRU
1. Operator panel
Location: L1
2. System board
Location: P1
Action/ Possible Failing FRU
1. Replace power supply "y".
2. Check the ac power source.
1. Notify support
2. Processor card, Location: P1-C1
3. System board, Location: P1 (See
note 3 on page 41.)
Chapter 5. Error Code to FRU Index