Table 6. UNIX LLI driver messages for the Ethernet
controller
pnt0-15
No more devices to open.
Explanation: The SunSoft Solaris driver
cannot find any more Ethernet controllers.
Action: Verify that additional IBM Netfinity
10/100 Fault Tolerant Adapters are present or
replace the Ethernet adapter that fails to
respond. If the problem persists, run the
diagnostic programs.
pnt0-17
Device fault...Reset initiated!
Explanation: The SunSoft Solaris driver has
been reset due to a device fault.
Action: Verify that additional IBM Netfinity
10/100 Fault Tolerant Adapters are present or
replace the Ethernet adapter that fails to
respond. If the problem persists, run the
diagnostic programs.
pnt0-19
IRQ found for PCnet hardware does not
match space.c (or pnt.conf)!
Explanation: This is a warning message
referring to the interrupt request (IRQ) that the
SunSoft Solaris driver found in the system.
Action: Ignore this message if you are sure
that this is what you want to do. Otherwise, run
the NETCONFIG program to match the
hardware settings
pnt0-20
add_intr_handler failed! Unknown interrupt
type.
Explanation: The interrupt request (IRQ) that
was specified, or the IRQ that was found,
conflicts with other devices in the server.
Action:
pnt0-21
add_intr_handler failed! Out of range
interrupt number.
Explanation: The interrupt request (IRQ) that
was specified, or the IRQ that was found,
conflicts with other devices in the server.
Action:
40
Netfinity 6000R Type 8682 Models 1RY, 2RY
Modify the hardware settings.
Run the NETCONFIG program to search
for another Ethernet controller.
• Modify the hardware settings.
• Run the NETCONFIG program to search
for another Ethernet controller.