Page 1
Hardware Maintenance Manual xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 3
Hardware Maintenance Manual xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 4
This publication was developed for products and services offered in the United States of America. IBM may not offer the products, services, or features discussed in this document in other countries, and the information is subject to change without notice.
IBM xSeries 330 Type 8674 and IntelliStation R Pro Type 6851. Important: This manual is intended for trained servicers who are familiar with IBM PC Server products. Before servicing an IBM product, be sure to review “Safety information”...
Lea atentamente todas las declaraciones de precaución y peligro ante de llevar a cabo cualquier operación. Online support Use the World Wide Web (WWW) to download Diagnostic, BIOS Flash, Device Driver files and documents. The Web address is: http://www.ibm.com/pc/support Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Small computer system interface messages ..12 The IBM Remote Supervisor Adapter ....56 Identifying problems using status LEDs ... . 13 Installation prerequisites .
Page 8
Testing the C2T chain ......112 IntelliStation R Pro ......144 Using C2T .
Page 10
If you receive an error, go to Chapter , “Symptom-to-FRU index,” on page 121. If the diagnostics completed successfully and you still suspect a problem, see “Undetermined problems” on page 137. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
IBM server/workstation Start Up Support. If you have access to the World Wide Web, you can obtain up-to-date information about your xSeries 330 or IntelliStation R Pro model and other IBM server/workstation products at the following World Wide Web addresses: http://www.ibm.com/eserver/xseries...
Thermal Units (BTU) per hour — Minimum: 0.08 kVA • Minimum configuration: 273 — Maximum: 0.22 kVA BTU (80 watts) • Maximum configuration: 751 BTU (220 watts) Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
What the xSeries 330 / IntelliStation R Pro offers The unique design of this server takes advantage of advancements in symmetric multiprocessing (SMP), data storage, and memory management. The server combines: • Impressive performance using an innovative approach to SMP The server supports up to two Pentium III microprocessors.
Light Path Diagnostic panel on the system board will also be on to further isolate the error. Diskette drive activity light: When this LED is on, it indicates that the diskette drive is in use. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Diskette-eject button: Push this button to release a diskette from the drive. Hard disk drive status light: Each of the hot-swap drives has a hard disk drive status light. When this amber LED is on continuously, the drive has failed. This status light is active only with a ServeRAID adapter installed in the server.
The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Turning off the server Turning off the server refers to the act of disconnecting the server from the power source. Complete the following steps to turn off the server: Refer to your operating system documentation for the proper procedure to shut down the operating system.
Page 18
Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Note: If the server/workstation does not have a hard disk drive, ignore any message that indicates that the drive is not installed. You will get these messages only when running the SCSISelect Utility. See “SCSI error codes” on page 134. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Table 2. SCSI messages. SCSI Messages Description One or more of the following might be causing the problem. • A failing SCSI device (adapter, drive, controller) • An improper SCSI configuration • Duplicate SCSI IDs in the same SCSI chain •...
Path TEMP Table 3. Light Path Diagnostics. Description Power supply error Memory error occurred TEMP System temperature exceeded maximum rating Microprocessor error Fan failed or operating slowly Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Table 3. Light Path Diagnostics. Description Voltage regulator module error Error occurred on service processor Error occurred on an adapter in PCI slot 1 or 2, or one of the PCI service devices integrated on the system board. See “Information panel system error LED” on page 123 for appropriate action. Diagnostic programs and error messages The server/workstation diagnostic programs are stored in upgradable read-only memory (ROM) on the system board.
If the hardware checks out OK but the problem persists during normal server/workstation operations, a software error might be the cause. If you suspect a software problem, refer to the information that comes with the software package. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Viewing the test log The test log will not contain any information until after the diagnostic program has run. Note: If you already are running the diagnostic programs, begin with step 3.. To view the test log: Turn on the server/workstation and watch the screen. If the server/workstation is on, shut down your operating system and restart the server/workstation: When the message F2 for Diagnostics appears, press F2.
Restart the server/workstation. The system begins the power-on self-test (POST) and BIOS flash. Select 1 - Update POST/BIOS from the menu that contains various flash (update) options. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
When prompted as to whether you want to save the current code to a diskette, select N. When prompted to choose a language, select a language (from 0 to 7) and press Enter to accept your choice. 10. Do not reboot your system at this time. 11.
NDIS 4.0 (Windows NT) driver messages This section contains the error messages for the NDIS 4.0 drivers. The explanation and recommended action are included with each message. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 29
Explanation: Single adapter found but multiple instances tried to load. Action: Using the Configuration/Setup utility, make sure that Ethernet is enabled, and that the slot containing the IBM Netfinity 10/100 Ethernet Adapter or the IBM 10/100 Etherjet PCI adapter is enabled. 0x17 Explanation: Slot parameter not specified in the registry.
Page 30
Explanation: Team nn. Primary adapter does not sense any Probes. Possible reason: partitioned Team. Action: Make sure the cables of the adapter team are connected to the same LAN segment. Reconfigure the team if necessary. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
CAUTION: When replacing the battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by...
Page 32
Tilt the battery so that you can insert it into the socket, under the battery clip. b. As you slide it under the battery clip, press the battery down into the socket. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Reinstall the server/workstation cover and connect the cables. Turn on the server/workstation. Start the Configuration/Setup Utility program and set configuration parameters. • Set the system date and time. • Set the power-on password. • Reconfigure the server/workstation. Temperature checkout Proper cooling of the system is important for proper operation and system reliability. For a typical xSeries server/workstation, you should make sure: •...
Page 34
Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
BIOS stored in the flash electronically erasable programmable ROM (EEPROM). — System Card Data Select this choice to view vital product data (VPD) for some server/workstation components. • Devices and I/O Ports Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 37
Select this choice to view or change the assignments for devices and input/output ports. This choice appears only on the full Configuration/Setup Utility main menu. This choice also allows you to enable or disable the integrated SCSI, and Ethernet controllers. —...
Page 38
— Core Chipset Control Select this choice to modify settings that control features of the core chip set on the system board. Attention: Do not make changes here unless directed to do so by an IBM authorized service representative. — Cache Control Select this choice to enable or disable the microprocessor cache.
If a memory error is detected during POST or memory configuration, the server/workstation will automatically disable the failing memory bank and continue operating with reduced memory capacity. If this occurs, you must manually enable the memory bank after the problem is corrected. Select Memory Settings from the Advanced Setup menu, use the arrow keys to highlight the bank that you want to enable;...
Attention: If an administrator password is set and then forgotten, it cannot be overridden or removed. You must replace the system board. The following table provides a summary of the password features. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Table 7. Power-on and administrator password features. Type of password Results Power-on password • Enter the password to complete the system startup. • A limited set of choices is available on the Configuration/Setup Utility main menu. Administrator • No password is required to start the system. password •...
After the drive that you want to view or format spins up, press Ctrl+A. Using the PXE boot agent utility program The PXE Boot Agent Utility program is a built-in, menu-driven configuration utility program that you can use to: Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
• Change startup (boot) order Attention: If you change the startup (boot) order using PXE Boot Agent Utility program, startup sequence settings in the Configuration/Setup Utility program might not function properly. • Select whether to display setup prompt • Set menu wait time •...
Utility diskette updates the ASM software only. It does not affect any device drivers. Updating the ASM firmware To update the ASM firmware using the xSeries 330/IntelliStation R Pro Advanced System Management Firmware Update Utility diskette, perform the following steps: Turn off the server.
configure the diskette drive as a startup device. See “Using the Configuration/Setup Utility program” on page 27. From the main menu, select Update System Management Firmware and press Enter. Follow the on-screen instructions to complete the update. If there is an error in loading the ASM software, try installing the software again. ASM Firmware Update Utility diskette menu choices The main menu options are as follows: •...
Select this choice to update configuration settings for the ASM processor. For more information, see “Updating the ASM firmware” on page 36. Exit Select this choice to exit from the xSeries 330/IntelliStation R Pro Advanced System Management Firmware Update Utility program. Configuring the ASM processor...
Page 47
After your server starts up and the main menu appears, select Configuration Settings and press Enter. Select General Settings and press Enter. Type a name for the ASM processor of your server in the Name field. This value can be up to 15 characters long. Type a number for the ASM processor of your server in the Number field.
Page 48
Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Danger: These statements indicate situations that can be potentially lethal or extremely hazardous to you. A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Major components of the xSeries 330 The following illustration shows the locations of major components in the server/workstation. Clear shield Air baffle Clip Terminator card Heatsink Memory module Microprocessor Fans Light Path Diagnostics Hard disk drive filler panel Hard disk drive Major components of the R Pro computer The following illustration shows the locations of major components in your computer.
The illustrations in the following sections show the components on the system board. System board options connectors The following illustration identifies the connectors on the system board. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 53
C2T (in) USB 1 port (U38) port (J13) Management port RS-485 (Advanced USB 2 (J53) System Management port (J15) interconnect) ports (J5) Serial port A C2T (out) (J52) port (U61) Serial port B (J51) Ethernet ports (J1) BIOS code PCI slot 2 page jumper 64 bit (J19)
• Back up all important data before you make changes to disk drives. • Have a small, flat-blade screwdriver available. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
• For a list of supported options for the server/workstation, refer to http://www.ibm.com/pc/us/compat on the World Wide Web. • For your convenience during setup and service you might want to have a separate location where you can temporarily connect the server/workstation to a power source (using a separate power cord), keyboard, monitor, and mouse (using a separate C2T device breakout cable).
Page 56
If you have additional servers/workstations to install, repeat steps 1 through 3 for each server/workstation. Install all external cables and power cords to the server/workstations. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Removing the cover The following information describes how to remove the cover. Cover release Screws lever Complete the following steps to remove the cover from the server/workstation: Review the information in “Before you begin” on page 46. Turn off the server/workstation and all attached devices and disconnect all external cables and power cords.
Note: To change the boot precedence, start the Configuration/Setup Utility, select Start Options from the main menu; then, select the PCI SCSI adapter boot option. Installing an adapter Complete the following steps to install an adapter: Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 59
Attention: When you handle electrostatic discharge (ESD) sensitive devices, take precautions to avoid damage from static electricity. For details on handling these devices, refer to “Handling electrostatic discharge-sensitive devices” on page 152. Review the safety precautions that are listed in Chapter , “Related service information,”...
Page 60
(J4) on the system board and attach it to the ServeRAID adapter. Air flow 10. Install the cover see “Removing the cover” on page 49. 11. Turn on the server/workstation. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
PCI slot to control the video functions for your monitor. Use only the device drivers supplied on the IntelliStation R Pro Support CD. The following illustration shows the location of the 33 MHz PCI expansion slots on the system board.
Turn off the computer and peripheral devices. Remove all external cables from the computer; then, remove the computer from the rack and remove the cover as shown. For more information, see “Removing Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 63
the cover” on page 49 for instructions. Cover release Screws lever Remove the expansion slot clip that holds the expansion slot cover in place by sliding it upward and off the frame of the computer. Note: The illustrations in this document might differ slightly from your hardware.
• Update the basic input/output system (BIOS) code on your xSeries 330 server. The latest level of BIOS code for your server is available from the IBM Support Web site, http://www.ibm.com/pc/support. For information about how to update the BIOS code, see the documentation that comes with your xSeries 330 server.
MIB is provided in the \MIB directory on the IBM Remote Supervisor Adapter Support CD that comes with the Remote Supervisor Adapter. • If you want to use the operating system shutdown feature of the Advanced...
• Adobe Acrobat Reader 3.0 or later (Adobe Acrobat Reader software is included on your IBM Documentation CD, and you can install it when you run the Documentation Browser) Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
To start the Documentation Browser on a system running with: • Windows NT, 95, 98, or 2000 do the following: If you have Autostart enabled, place the IBM Documentation CD in your CD-ROM drive. When you close the CD-ROM drive, the Documentation Browser program starts automatically.
The Remote Supervisor Adapter option contains the following items: • Remote Supervisor Adapter • Power-supply adapter • Power cord • 20-pin ribbon cable • Advanced System Management link cable (CAT 5 Ethernet cable) Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 69
Attention: To avoid damage to the Ethernet connector on the Remote Supervisor Adapter, do not plug the ASM Interconnect module into the Ethernet (RJ-45) port. • IBM Remote Supervisor Adapter Support CD This CD helps you configure hardware and install device drivers. •...
Attention: When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details about handling static-sensitive devices, see “Handling electrostatic discharge-sensitive devices” on page 152. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 71
Your server comes with riser cards installed in the two peripheral component interconnect (PCI) adapter slots on the system board. The following illustration shows the location of the 33 MHz PCI expansion slots on the system board. PCI slot 2 64 bit 33 MHz (J23) PCI slot 1...
Page 72
10. Connect one end of the ASM link cable (Category 5 cable) to the ASM Interconnect module, and the other end to the ASM Interconnect port that is located on the back of your server. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
ASM link cable ASM Interconnect module 11. Turn on the server. Continue with “Connecting the power-supply adapter”. Connecting the power-supply adapter You may attach the power-supply adapter that comes with the Remote Supervisor Adapter. After you connect the power supply adapter to the Remote Supervisor Adapter, you can use the power cord to connect the power supply adapter to a properly grounded electrical outlet or use the universal power cord (comes with the Remote Supervisor Adapter) to connect the power supply adapter to a power...
ASM Web interface using LAN using the Ethernet port “Cabling the Ethernet LAN the HTTP protocol port” on page 67 Text-based user interface using the TELNET protocol Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Table 9. Cabling tasks to enable remote access to the Remote Supervisor Adapter. User interface to Remote Connection to Remote For the cabling procedure, see: Supervisor Adapter Supervisor Adapter Text-based user interface Serial (COM) port “Cabling the serial (COM) using a modem or a null port”...
Remote Supervisor Adapter and to update the firmware. This Utility program is a DOS utility on the IBM Remote Supervisor Adapter Support CD that comes with the Remote Supervisor Adapter. You can obtain the latest firmware code from the IBM Support Web site, http://www.ibm.com/pc/support.
Page 77
Use the Up Arrow and Down Arrow keys (↑ and ↓) to select Update System Management Firmware; then, press Enter. A warning window opens. Press Enter to continue. The Firmware Update Options Menu window opens. Use the arrow keys to select Normal Flash - All subsystems; then, press Enter. Installing options...
Page 78
When the Remote Supervisor Adapter firmware update process is complete, press Enter to return to the Utility program main window. Continue with “Configuring your system to enable remote access to the Remote Supervisor Adapter” on page 71. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
PPP For detailed information about using the ASM Web interface and the text-based user interface, see the IBM Remote Supervisor Adapter User’s Guide for the xSeries 330. Configuring the Ethernet settings If you have an accessible, active, and configured dynamic host configuration protocol (DHCP) server on your network, the hostname, IP address, gateway address, subnet mask, and DNS server IP address are set automatically.
Page 80
IP Address Type the IP address of the Remote Supervisor Adapter. Subnet Mask Type the subnet mask used by the Remote Supervisor Adapter. The default value is 255.255.255.0. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
2. Turn on the server. Insert the IBM Remote Supervisor Adapter Support CD into the CD-ROM drive and close the CD-ROM drive before the server completes POST. The CD starts automatically and the IBM Remote Supervisor Utility window opens.
The PPP enables TCP/IP communication over the serial port, which enables Web- based management and TELNET sessions over a modem. To set up PPP, complete the following steps: Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 83
2. Turn on the server. Insert the IBM Remote Supervisor Adapter Support CD into the CD-ROM drive and close the CD-ROM drive before the server completes POST. Note: If you do not insert the CD and close the CD-ROM drive before POST completes, you must restart the server with the CD in the CD-ROM drive.
Note: You do not need to restart the server if you are running the Windows NT operating system. See the IBM Remote Supervisor Adapter User’s Guide for the xSeries 330 for detailed instructions about completing the configuration of the Remote Supervisor Adapter features.
Remote Supervisor Adapter that is the main interconnect gateway for the ASM interconnect network. The latest level of firmware is available on the IBM Support Web site at http//:www.ibm.com/support. The Remote Supervisor Adapter forwards the ASM information generated by the servers attached to the ASM interconnect bus to other servers on your Ethernet network.
ASM Interconnect modules or CAT 5 or CAT 3 Ethernet cables. This table lists some of the IBM Netfinity and IBM xSeries products and indicates if they have an integrated RS-485 ASM interconnect connection, or if you need to use an ASM Interconnect module to set up the ASM interconnect network.
Table 11. ASM interconnect network server list. Server Name ASM Interconnect module needed Netfinity 4500R or xSeries 340 xSeries 330 Netfinity 6000R or xSeries 350 Netfinity 7600 Netfinity 7100 Installing the ASM Interconnect module on the xSeries The ASM Interconnect module connects the Remote Supervisor Adapter to the ASM interconnect network.
Server 3 Server 4 Server 5 xSeries 330 xSeries 330 xSeries 330 xSeries 330 Note: There are no Remote Supervisor Adapters installed in servers 2 through 5. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 89
In the following example, a Remote Supervisor Adapter is installed in an xSeries 330 server. This view shows the top server in a rack of xSeries servers with a Remote Supervisor Adapter installed. The xSeries 330 with the Remote Supervisor Adapter will act as the network interconnect, forwarding system-management data generated by the other systems in the ASM interconnect network bus to the system management administration system that is connected to the network.
This is an environment with different models of servers. Hard disk drives The server/workstation supports two 1-inch (26 mm) slim 3.5-inch low voltage differential (LVD) hard disk drives. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Notes: You can hot-swap a hard disk drive only if a ServeRAID adapter configured as RAID1 is installed in the system. If you use any other ServeRAID or SCSI configuration, you cannot hot-swap the hard disk drive. Each hard disk drive tray has a status and an activity light located on the upper-right corner of tray (see “Server controls and indicators”...
DIMM slot 1. Note: Install additional DIMMs in the following order: DIMM connector 2, then 3, then 4. (See the following illustration for memory connector locations.) Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Connector 1 Connector 2 Connector 3 Connector 4 Installing memory modules Complete the following steps to install a DIMM: Attention: When you handle electrostatic discharge-sensitive devices (ESD), take precautions to avoid damage from static electricity. For details on handling these devices, refer to “Handling electrostatic discharge-sensitive devices”...
With SMP, certain operating systems and application programs can distribute the processing load between the microprocessors. This enhances performance for database and point-of-sale applications, integrated manufacturing solutions, and other applications. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Microprocessor internal clock frequencies and external clock frequencies must be identical. See the serverProven list at http://www.ibm.com/pc/compat for a list of microprocessors for use with the server/workstation.
Page 96
Align and place the clip over the heat sin; then, snap the clip into place over the heat sink with the heat sink release lever in the up position. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Note: If you remove the microprocessor later, remember to install the terminator card in the appropriate microprocessor connector. d. Press the heat sink release lever down into the locked position once the clip is in place. Replace the clear shield, then go to “Installing the cover” on page 93. Note: It is very important to replace the clear shield.
Page 98
Note: If a terminator card is being installed in microprocessor slot #1, it is not necessary to replace the adapter retainer latch. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Slot Heatsink release lever Clip Heatsink Top view of Microprocessor heatsink Retainer clip Terminator card Fan assembly replacement The server/workstation comes with six replaceable fans. Attention: Replace a fan that has failed within 48 hours to help ensure proper cooling. The following illustration shows the replacement of a fan.
Page 100
Start up the system, the system error light will either remain on or turn off. If the system error light remains on you will have to turn off the server/workstation to perform further troubleshooting. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Installing the cover The following information describes the cover installation procedure. Screws To install the server/workstation cover: Clear any cables that might impede the replacement of the clear shield or the cover. Install the clear shield, if it was removed. Note: Thermal considerations require that the clear shield be installed before operating the server/workstation.
• Console ports • Serial port • Universal Serial Bus (USB) ports • Ethernet ports • Advanced System Management (ASM) ports • Audio ports • Video ports Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Console ports There are two console ports on the rear of your computer labeled IN and OUT. Use only the OUT port to connect the computer to the console (mouse and keyboard). Device breakout cable A keyboard and mouse or pointing device are connected to your computer through the device breakout cable.
Management Port Used by Advanced System Management Processor to utilize modem dial up functions. Viewing or changing the serial-port assignments: To view or change the serial-port assignments: Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 105
Restart the computer and watch the monitor screen. When the message Press F1 for Configuration/Setup appears, press F1. From the main menu, select Devices and I/O Ports; then, press Enter. Note: The Devices and I/O Ports choice appears only on the full configuration menu.
USB technology provides up to 12 megabits-per-second (Mbps) speed with a maximum of 127 external devices and a maximum signal distance of five meters (16 ft). per segment. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Mbps) on the network and then set the controllers to operate at the appropriate rate. ™ The IBM 10/100 Ethernet Adapter or the IBM 10/100 EtherJet PCI family of adapters are optional redundant network adapters that you can install in your server.
Page 108
If these devices do not support 802.1p or if you are not sure, use High Priority Queue (HPQ) to prioritize network traffic. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 109
802.1p. • The adapters on these devices must support 802.1p. The Ethernet controller in your computer, all IBM Netfinity 10/100 Ethernet Security Adapters, and IBM 10/100 Ethernet Server Adapters support 802.1p. • The adapter cannot be assigned to an adapter team.
Page 110
Table 17. Ethernet RJ-45 connector pin-number assignments.. Signal Signal Transmit data+ Not connected Transmit data- Receive data - Receive data+ Not connected Not connected Not connected Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Audio ports The audio adapter is standard in the IntelliStation R Pro workstation. The audio adapter ports are standard ports. The computer has an integrated audio controller. Using the audio controller, you can record sound and music. You can also play sound with multimedia applications.
Management Port Used by Advanced System Management Processor to utilize modem dial up functions. Viewing or changing the serial-port assignments: To view or change the serial-port assignments: Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Restart the server/workstation and watch the monitor screen. When the message Press F1 for Configuration/Setup appears, press F1. From the main menu, select Devices and I/O Ports; then, press Enter. Note: The Devices and I/O Ports choice appears only on the full configuration menu.
(secondary) controller. This switching occurs without any user intervention. When the primary link is restored to an operational state, the Ethernet traffic switches back to the primary Ethernet controller. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 115
Priority Packet information is available on the IBM Networking Web site at: http://www.ibm.com/networking/support Priority Packet prioritizes traffic based on priority filters.
Page 116
Double-click the Network icon in the Control Panel window. On the Adapters tab, select the adapter you want to be on the VLAN and select Properties. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
In IBMSet, select Join VLAN. Note that VLANs cannot be assigned to adapters that are already defined to have an adapter teaming option. Enter the VLAN ID and VLAN name. The VLAN ID must match the VLAN ID of the switch. The ID range is from 1 to 1000. The VLAN name is for information only and does not need to match the name on the switch.
485 (B) connector and the other end of the cable into the RS-485 (A) connector of the next server. Continue connecting the servers together in this manner until you reach the second-to-last server in the ASM bus. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Connect a cable from the RS-485 (B) connector of the second-to-last server to the RS-485 (B) connector of the last server. Refer to the following illustration to see how to connect the ASM bus. Ethernet cable with RJ-45 connectors RS-485(A) RS-485(B) RS-485(A) RS-485(B)
1 in the C2T chain is lit, indicating that it is selected. If it is not, press the Select button. Verify that the monitor is working. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Start up an operating system that has a mouse or pointing device driver and verify that the mouse or pointing device buttons function. Test your keyboard by typing a few words within an application. Press NumLock on the keyboard twice, and then press the number of the server to test next, and then press Enter.
Page 122
Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Hard disk drive backplane To remove the hard disk drive backplane: Notes: The IntelliStation R Pro does not have hard disk backplanes. Read“Safety information” on page 149 and “Before you begin” on page 46 Power off the server/workstation. Remove the cover. See “Removing the cover” on page 49.
Note: Read“Safety information” on page 149 and “Before you begin” on page 46. Power off the server/workstation. Remove the cover. See “Removing the cover” on page 49. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
BIOS flash code from the following Web site. At the Web site, perform a search on the keywords “IntelliStation BIOS". http://www.pc.ibm.com/us/files.html If Web access is not available to you, use the IBM IntelliStation R Pro (Type 6851) BIOS Update diskette provided with this FRU. Initializing the system board...
Page 128
12. Highlight Exit Setup; then, press Enter. 13. Highlight Yes, save and exit the Setup Utility; then, press Enter. Initialization of the new system board is complete. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Symptom-to-FRU index This index supports xSeries 330/IntelliStation R Pro servers/workstations. The Symptom-to-FRU lists symptoms, errors, and the possible causes. The most likely cause is listed first. Use this Symptom-to-FRU index to help you decide which FRUs to have available when servicing the computer.
Page 130
30) Battery 3-3-2 (Critical SMBUS error Disconnect the server/workstation power cord from outlet, wait 30 occurred) seconds and retry. System Board DIMMs DASD Backplane DASD Power Cable Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Beep/Symptom FRU/Action 3-3-3 (No operational memory in Install or reseat the memory modules, then do a 3 boot reset. (See “Using system) the Configuration/Setup Utility program” on page 27) DIMMs System Board Two Short Beeps (Information only, Run Diagnostics the configuration has changed) Run Configuration/Setup Three Short Beeps DIMM...
Page 132
System over recommended temperature for CPU X (where X is CPU number,) (CPU LED also on) CPU X System Board System Board over recommended temperature System Board. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Diagnostic error codes Note: In the following error codes, if XXX is 000, 195, or 197 do not replace a FRU. The description for these error codes are: The test passed. The Esc key was pressed to abort the test. This is a warning error and may not indicate a hardware failure.
Page 134
DIMM Location slots 1-4 where NN = DIMM location. "Memory Settings" on page 30) Note: NN 1=DIMM 1 NN 2=DIMM 2 NN 3=DIMM 3 NN 4=DIMM 4 System Board Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 135
Error Code/Symptom FRU/Action 201-XXX-999 (Multiple DIMM failure, see See error text for failing DIMMs error text) System Board 202-XXX-001 (Failed System Cache test) Microprocessor 1 System Board 202-XXX-002 (Failed System Cache test) Microprocessor 2 System Board 206-XXX-000 (Failed Diskette Drive test) Try test with another diskette Cable Diskette Drive...
The diskette contains the necessary files to start the server/workstation. The software program is OK. Cable is installed correctly (proper orientation) Run Diskette Drive Diagnostics Cable Diskette Drive System Board Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Error Symptom FRU/Action Monitor problems (general). Some IBM Monitor monitors have their own self-tests. If you Run Video Diagnostics. If diagnostics pass, the problem may be a suspect a problem with the monitor, refer to video driver. the information that comes with the...
Page 138
BIOS installed, update the BIOS to the latest level and run the diagnostic program again. 229 (Cache error) Processor Optional Processor (if installed) Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 139
Error Code/Symptom FRU/Action 262 (DRAM parity configuration error) Run configuration / setup Battery System Board 289 (DIMM has been disabled by the user Run Configuration/Setup, if disabled by user or system, see "Memory Settings" on page Disabled DIMM, if not disabled by user. 30.) System Board.
Page 140
2462 (Video memory configuration error) Video Adapter (if installed) System Board 5962 (IDE CD-ROM configuration error) Run Configuration/Setup CD-ROM Drive CD-ROM Power Cable IDE Cable System Board Battery Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 141
Error Code/Symptom FRU/Action 8603 (Pointing Device Error) Pointing Device System Board 00019501 (Processor 1 is not functioning - Processor 1 check VRM and processor LEDs) System Board 00019502 (Processor 2 is not functioning - Processor 2 check VRM and processor LEDs) System Board 00019701 (Processor 1 failed) Processor 1...
Power Supply "X" Temperature Fault Ensure system is being properly cooled; see “Temperature (level-critical; power supply "x" had over checkout” on page 25. temperature condition) Replace Power Supply "X" Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Message Action System board is over recommended Ensure system is being properly cooled; see “Temperature temperature (level-warning; system board checkout” on page 25. is over recommended temperature) Replace system board System board is under recommended Ambient temperature must be within normal operating temperature (level-warning;...
The table below provides the appropriate actions to take for each bus number listed. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Message Action Failure reading I2C device. Check devices Replace system board on bus 0. Failure reading I2C device. Check devices Front Panel on bus 1. Replace system board Failure reading I2C device. Check devices Replace DASD backplane on bus 2. Replace system board Failure reading I2C device.
Page 146
System Board. If you suspect a networking problem and all the system tests pass, suspect a network cabling problem external to the system. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 148
Power Cord (All Models) 36L8886 20.0 GB ATA-100 Hard Disk Drive (Model 12X) 19K1565 Heatsink clip (All Models) 06P6240 18.2 GB SCSI Hot Swap 10K rpm (Model 11X) (optional) 19K0614 Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
IntelliStation R Pro The IntelliStation R Pro Type 6851 parts listing supports model types 10x, 11x, 12x, 13x. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 153
Index IntelliStation R Pro Type 6851 (Models 10x, 11x, 12x, 13x) FRU Number Bracket/Baffle (All Models) 00N6993 Heat Sink/Clip Assembly (All Models) 24P0653 Terminator Card (All Models) 25P1866 Fan with Connector (All Models) 00N6991 3.5 Floppy Disk Drive, 12.7MM (All Models)
37L2556 Belgium/UK 37L2557 Bulgarian 37L2558 Czech 37L2559 Danish 37L2560 Dutch 37L2561 French 37L2562 German 37L2563 Greek 37L2564 Hebrew 37L2565 Hungarian 37L2566 Korean 02K0901 Iceland 37L2567 Italy 37L2568 Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Keyboard FRU No. Norwegian 37L2569 Polish 37L2570 Portuguese 37L2571 Romanian 37L2572 Russian 37L2573 Serbian/Cyrillic 37L2574 Slavic 37L2575 Spanish 37L2576 Swedish/Finn 37L2577 Swiss, F/G 37L2578 Turkish 37L2579 Turkish 37L2580 UK English 37L2581 Yugosl/Lat 37L2582 US English-EMEA 37L2583 Chinese/US 37L2585 Thailand 37L2587 French Canadian 37L0913 Power cords...
Page 156
(South), Liberia, Mexico, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Suriname, Taiwan, Trinidad (West Indies), Venezuela United States of America 6952301 (110) 1838574 (220) 36L8886 (220V/15A) Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Safety information The following section contains the safety information that you need to be familiar with before servicing an IBM mobile computer. General safety Follow these rules to ensure general safety: •...
— Stand on suitable rubber mats (obtained locally, if necessary) to insulate you from grounds such as metal floor strips and machine frames. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
This guide addresses only those items. However, good judgment should be used to identify potential safety hazards due to attachment of non-IBM features or options not covered by this inspection guide.
— Use an ESD common ground or reference point when working on a double- insulated or battery-operated system. You can use coax or connector-outside shells on these systems. — Use the round ground-prong of the ac plug on ac-operated computers. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Korean • Spanish Important: All caution and danger statements in this IBM documentation begin with a number. This number is used to cross reference an English caution or danger statement with translated versions of the caution or danger statement in this section.
Page 162
Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure. DANGER: Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the following: Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 163
Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam. • Statement 4 ≥18 kg (37 lbs) ≥32 kg (70.5 lbs) ≥55 kg (121.2 lbs) CAUTION: Use safe practices when lifting.
Page 164
Conecte os cabos de sinal aos Remova os cabos de sinal dos conectores. conectores. Remova todos os cabos dos dispositivos. Conecte os cabos de alimentação às tomadas. LIGUE os dispositivos. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 165
Aqueça a mais de 100°C (212°F) • Conserte nem desmonte Para descartar a bateria, entre em contato com a área de atendimento a clientes IBM, pelo telefone (011) 889-8986, para obter informações sobre como enviar a bateria pelo correio para a IBM.
Page 166
CUIDADO: Instrução 10 CUIDADO: Não coloque nenhum objeto com peso superior a 82 kg (180 lbs.) sobre dispositivos montados em rack. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 174
Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 175
Important: Toutes les consignes Attention et Danger indiquées dans la bibliothèque IBM documentation sont précédées d'un numéro. Ce dernier permet de mettre en correspondance la consigne en anglais avec ses versions traduites dans la présente section. Par exemple, si une consigne de type Attention est précédée du chiffre 1, ses traductions sont également précédées du chiffre 1 dans la présente section.
Page 176
Rayonnement laser lorsque le carter est ouvert. évitez de regarder fixement le faisceau ou de l'observer à l'aide d'instruments optiques. évitez une exposition directe au rayon. Notice n° 4 Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 177
≥18 kg (37 lbs) ≥32 kg (70.5 lbs) ≥55 kg (121.2 lbs) ATTENTION: Faites-vous aider pour soulever ce produit. Notice n° 5 ATTENTION: Le bouton de mise sous tension/hors tension de l'unité et l'interrupteur d'alimentation du bloc d'alimentation ne coupent pas l'arrivée de courant électrique à...
Page 178
Zuerst Netzstecker von Steckdose lösen. Zuerst alle Kabel an Einheiten Signalkabel von Anschlußbuchsen lösen. anschließen. Alle Kabel von Einheiten lösen. Signalkabel an Anschlußbuchsen anschließen. Netzstecker an Steckdose anschließen. Gerät einschalten. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 179
Hinweis 2 ACHTUNG: Eine verbrauchte Batterie nur durch eine Batterie mit der IBM Teilenummer 33F8354 oder durch eine vom Hersteller empfohlene Batterie ersetzen. Wenn Ihr System ein Modul mit einer Lithium-Batterie enthält, ersetzen Sie es immer mit dem selben Modultyp vom selben Hersteller. Die Batterie enthält Lithium und kann bei unsachgemäßer Verwendung, Handhabung oder Entsorgung explodieren.
Page 180
Stromversorgung des Servers auszuschalten, muß sichergestellt werden, daß alle Netzkabel aus den Netzsteckdosen herausgezogen wurden. Hinweis 10 ACHTUNG: Keine Gegenstände, die mehr als 82 kg wiegen, auf Rack-Einheiten ablegen. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 181
Importante: Tutti gli avvisi di attenzione e di pericolo riportati nella pubblicazione IBM documentation iniziano con un numero. Questo numero viene utilizzato per confrontare avvisi di attenzione o di pericolo in inglese con le versioni tradotte riportate in questa sezione.
Page 182
Avviso 2 ATTENZIONE: Quando si sostituisce la batteria al litio, utilizzare solo una batteria IBM con numero parte 33F8354 o batterie dello stesso tipo o di tipo equivalente consigliate dal produttore. Se il sistema di cui si dispone è provvisto di un modulo contenente una batteria al litio, sostituire tale batteria solo con un tipo di modulo uguale a quello fornito dal produttore.
Page 183
≥18 kg ≥32 kg ≥55 kg ATTENZIONE: Durante il sollevamento della macchina seguire delle norme di sicurezza. Avviso 5 ATTENZIONE: Il pulsante del controllo dell'alimentazione situato sull'unità e l'interruttore di alimentazione posto sull'alimentatore non disattiva la corrente elettrica fornita all'unità. L'unità potrebbe disporre di più di un cavo di alimentazione. Per disattivare la corrente elettrica dall'unità, accertarsi che tutti i cavi di alimentazione siano scollegati dalla sorgente di alimentazione.
Page 184
Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 186
Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 187
Importante: Todas las declaraciones de precauciín de esta IBM documentation empiezan con un número. Dicho número se emplea para establecer una referencia cruzada de una declaraciín de precauciín o peligro en inglés con las versiones traducidas que de dichas declaraciones pueden encontrarse en esta secciín.
Page 188
Cuando se abre, hay radiaciín láser. No mire fijamente el rayo ni lleve a cabo ningún examen directamente con instrumentos ípticos; evite la exposiciín directa al rayo. Declaración 4 Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 189
≥18 kg ≥32 kg ≥55 kg PRECAUCIÓN: Tome medidas de seguridad al levantar el producto. Declaración 5 PRECAUCIÓN: El botín de control de alimentaciín del dispositivo y el interruptor de alimentaciín de la fuente de alimentaciín no apagan la corriente eléctrica suministrada al dispositivo. Es posible también que el dispositivo tenga más de un cable de alimentaciín.
We want to know your opinion about this manual (part number 24P2923). Your input will help us to improve our publications. Please photocopy this survey, complete it, and then fax it to IBM HMM Survey at 919-543-8167 (USA). Name: _________________________________________...
IBM intends to make these available in all countries in which IBM operates. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Subject to IBM’s valid...
Sun Microsystems, Inc. in the United States, other countries, or both. Other company, product, and service names may be trademarks or service marks of others. Hardware Maintenance Manual: xSeries 330 Type 8674 and IntelliStation R Pro Type 6851...
Page 194
IBM@ Part Number: 24P2923 File Number: Printed in the United States of America on recycled paper containing 10% recovered post-consumer fiber. 24P2923 0424P2923...