Error
Code/Symptom
1303
(cable from system
board to power
backplane not
found)
1304
(cable to diagnostic
LED board not
found)
1600
(Netfinity Advanced
System Manage-
ment processor is
not functioning) Do
the following before
replacing a FRU:
1. Ensure that a
jumper is not
installed on
J5.
2. Remove the
ac power to
the system,
wait 20
seconds; then,
re-connect the
ac power.
Wait 30
seconds; then,
power-on the
system.
FRU/Action
1. Cable
2. Power Backplane
3. System Board
1. Cable
2. Diagnostic LED Board
3. System Board
1. System Board
2. Service Processor Board
Symptom-to-FRU index