Note: The System Error LED will also be on.
Diagnostic
Panel LED
NMI LED on
Note: NMI LED
can only
be turned
off by
removing
ac power
from
system,
then
restoring
ac power.
PCI A LED on
PCI B LED on
PCI C LED on
PS1 LED on
PS2 LED on
1. Reboot the system.
2. Check the System Error Log.
1. Check System Error Log for
additional information.
2. PCI card in slot 1. See "System
board component locations" on
page 54.
3. Remove all PCI adapters from
slots 1-6.
4. Replace failing PCI adapter.
5. System Board.
1. Check System Error Log for
additional information.
2. PCI card in slots 2-4. See
"System board component
locations" on page 54.
3. Remove all PCI adapters from
slots 1-6.
4. Replace failing PCI adapter.
5. System Board.
1. Check System Error Log for
additional information.
2. PCI card in slots 5-6. See
"System board component
locations" on page 54.
3. Remove all PCI adapters from
slots 1-6.
4. Replace failing PCI adapter.
5. System Board.
1. Check the DC Good LED on
power supply 1. If off, replace
power supply 1.
2. Power Backplane.
1. Check the DC Good LED on
power supply 2. If off, replace
power supply 2.
2. Power Backplane.
Symptom-to-FRU index
FRU/Action
159