IBM 6000R - Netfinity - 8682 Hardware Maintenance Manual page 16

Hardware maintenance manual
Hide thumbs Also See for 6000R - Netfinity - 8682:
Table of Contents

Advertisement

• Video:
— S3 video controller
— Compatible with SVGA and VGA
— 8 MB video memory
• Size (4 U)
— Height: 178 mm (7 in.) (4 U)
— Depth: 711.2 mm (28 in.)
— Width: 482.6 mm (19 in.)
— Weight: 34.9 kg (77 lb.) to 50.4 kg (111 lb.)
depending upon configuration
• Integrated functions:
— Netfinity Advanced System Management proces-
sor with Light Path diagnostics
— Dual channel Ultra160 SCSI controller (one inter-
nal and one external channel) (non-RAID)
— One 10BASE-T/100BASE-TX AMD Ethernet con-
troller
— Two serial ports
— One parallel port
— Two universal serial bus ports
— Keyboard port
— Mouse port
— Video port
• Acoustical noise emissions:
— Sound power, idling: 6.3 bel maximum
— Sound power, operating: 6.3 bel maximum
— Sound pressure, operating: 48 dBa maximum
• Environment:
— Air temperature:
— Humidity:
• Heat output:
Approximate heat output in British Thermal Units (BTU)
per hour
— Minimum configuration:461 BTU (0.14 kilowatts
per hour)
— Maximum configuration: 1796 BTU (0.53 kilowatts
per hour)
• Electrical input:
— Sine-wave input (50-60 Hz) required
— Input voltage low range:
— Input voltage high range:
4
Netfinity 6000R Type 8682 Models 1RY, 2RY
– Server on: 10º to 35º C (50º to 95º F). Alti-
tude: 0 to 914 m (3000 ft.)
– Server on: 10º to 32º C (50º to 89.6º F). Alti-
tude: 914 m (3000 ft.) to 2133 m (7000 ft.)
– Server off: 10º to 43º C (50º to 110º F). Maxi-
mum altitude: 2133 m (7000 ft.)
– Server on: 8% to 80%
– Server off: 8% to 80%
– Minimum: 90 V ac
– Maximum: 137 V ac
– Minimum: 180 V ac
– Maximum: 265 V ac

Advertisement

Table of Contents
loading

Table of Contents