Error
Code/Symptom
020-XXX-003
(Failed Hot-Swap
Slot 3 PCI Latch
test)
020-XXX-004
(Failed Hot-Swap
Slot 4 PCI Latch
test)
020-XXX-005
(Failed Hot-Swap
Slot 5 PCI Latch
test)
020-XXX-006
(Failed Hot-Swap
Slot 6 PCI Latch
test)
030-XXX-000
(Failed Internal
SCSI interface
test)
030-XXX-00N
(Failed SCSI test
on PCI slot N.
Check system
error log before
replacing a FRU.)
035-XXX-099
035-XXX-S99
(Failed RAID test
on PCI slot S. S =
number of failing
PCI slot. Check
System Error Log
before replacing a
FRU.)
035-XXX-SNN
(Check System
Error Log before
replacing a FRU.
S = number of
failing PCI slot; NN
= SCSI ID of failing
fixed disk.)
162
Netfinity 6000R Type 8682 Models 1RY, 2RY
FRU/Action
1. PCI Hot-Swap Latch
Assembly
2. System Board
1. PCI Hot-Swap Latch
Assembly
2. System Board
1. PCI Hot-Swap Latch
Assembly
2. System Board
1. PCI Hot-Swap Latch
Assembly
2. System Board
1. System Board
1. Adapter in Slot N
1. No adapters were found.
2. If adapter is installed re-check
connection.
1. Adapter
2. SCSI Backplane
3. Cable
1. Fixed Disk with SCSI ID NN
on RAID adapter in PCI slot
S.