Table 2. Ethernet troubleshooting chart
Ethernet
controller
problem
The Ethernet
Transmit/
Receive
Activity light
does not
light.
Data is
incorrect or
sporadic.
The Ethernet
controller
stopped
working
when
another
adapter was
added to the
server.
The Ethernet
controller
stopped
working
without
apparent
cause.
30
Netfinity 6000R Type 8682 Models 1RY, 2RY
Suggested Action
Check the following:
Note: The Ethernet Transmit/Receive
Activity LED illuminates only when
data is sent to or by this Ethernet
controller.
• Make sure that you have loaded the
network device drivers.
• The network might be idle. Try
sending data from this workstation.
• Run diagnostics on the LEDs.
• The function of this LED can be
changed by device driver load
parameters. If necessary, remove
any LED parameter settings when
you load the device drivers.
Check the following:
• Make sure that you are using
Category 5 cabling when operating
the server at 100 Mbps.
• Make sure that the cables do not run
close to noise-inducing sources like
fluorescent lights.
Check the following:
• Make sure that the cable is
connected to the Ethernet controller.
• Make sure that the PCI system BIOS
is current.
• Reseat the adapter.
• Determine if the interrupt (IRQ)
setting assigned to the Ethernet
adapter is also assigned to another
device in the Configuration/Setup
Utility program.
Although interrupt sharing is allowed
for PCI devices, some devices do not
function well when they share an
interrupt with a dissimilar PCI device.
Try changing the IRQ assigned to the
Ethernet adapter or the other device.
Check the following:
• Run diagnostics for the Ethernet
controller.
• Try a different connector on the hub.
• Reinstall the device drivers. Refer to
the operating-system documentation
and to the ServerGuide information.

Advertisement

Table of Contents
loading